Fast delivery within 72 Hours

Wago 2857-569

Short description:WAGO’s 1-phase power measurement module monitors and reports signal states with up to two switching thresholds. The sensor and status information that is collected is also converted…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Short description:WAGO’s 1-phase power measurement module monitors and reports signal states with up to two switching thresholds. The sensor and status information that is collected is also converted to a standard analog signal. Current, voltage, effective power, apparent power or reactive power can be selected as the measured variable. Additionally, both frequency and phase angle are displayed.Features:A relay with changeover contact reacts to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values).Adjustable software filterAnalog unipolar/bipolar signals (current/voltage) at outputAdditional digital signal output for configured measurement range limitsThe digital output can be configured as a frequency generator or pulse output (S0 interface).

Specification

Notes

NoteThis product is powered by 24 VDC, which can be bridged using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 6 A is not exceeded., Additional setting options via the WAGO Interface Configuration Software

Technical data - Configuration

Configuration optionsWAGO Interface Configuration Software

Technical data - Input

Input signal typeVoltage, Current
Input signal (voltage)500 V AC/DC (IN 2.1; per EN 61010-1), 300 V AC/DC (IN 2.1; per UL 61010-1), 250 V AC/DC (IN 2.2), 30 V AC/DC (IN 2.3)
Input signal (current)1 A AC/DC (IN 3.1), 5 A AC/DC (IN 3.2), 8 A AC/DC (IN 3.3)
Frequency range15 … 400 Hz
Input current (max.)1.2 × IN (≤ 60 °C); 1 × IN (60 … 70 °C)
Input voltage (max.)1.2 × UN
Response threshold (voltage)500 mVAC / 600 mVDC (IN 2.1), 50 mVAC / 500 mVDC (IN 2.2), 20 mVAC / 100 mVDC (IN 2.3)
Response threshold (current)1.5 mAAC / 7.5 mADC (IN 3.1), 3 mAAC / 10 mADC (IN 3.2), 7.5 mAAC / 12 mADC (IN 3.3)
Resolution (voltage)50 mV (IN 2.1), 30 mV (IN 2.2), 5 mV (IN 2.3)
Resolution (current)1 mA (for all measurement ranges)

Technical data - Output (analog)

Output signal typeCurrent, Voltage
Output signal (voltage)±12 V (SELV)
Output signal (current)±24 mA (SELV)
Load impedance (voltage output)≥ 2 kΩ
Load impedance (current output)≤ 600 Ω

Technical data - Output (digital)

Switching voltage (DO) max.Applied supply voltage − 0.3 V
Continuous current (DO) max.100 mA (no internal restriction)
Number of switching thresholds (DO)2 (max.)
Configurable rise/fall delay time (DO)0 … 60 s (via software)
Configurable functions (DO)Threshold Value Switch, Disabled, US/GND switching, Threshold value switch, Frequency generator, Pulse output (S0 interface)
Setting range (frequency generator)0.3 … 100 Hz
Setting range (pulse output)1000 … 1 pulses/kW(h)

Technical data - Output (relay)

Number of changeover/switchover contacts1
Switching Voltage, Max.250 VAC
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Number of switching thresholds (relay)1 or 2 (adjustable)
Configurable rise/fall delay time (relay)0 … 60 s (via software)

Technical data - Signal processing

Measurement methodTrue RMS measurement (TRMS)
Measured variables (calculated)Active power, Apparent power, Reactive power, Mains frequency, Phase angle
Limit frequency2 kHz
Software filter (adjustable)Filter level: 1 … 30
Step response (max.)350 ms (for default settings)

Technical data - Measurement error

Transmission error (max.)≤ 0.5 % for current and voltage (of the full scale value)

Technical data - Power supply

Power supply type24 VDC
Nominal supply voltage U<sub>S</sub>24 VDC (SELV)
Supply voltage range±30 %
Current consumption at nominal supply voltage≤ 70 mA (+ IDO)

Safety and protection

Rated voltage600 V; 300 V (UL)
Measurement category per EN/UL 61010-2-030CAT III (input)
Note on insulation parametersThe digital output (DO) operates at the supply potential. The service interface operates at the potential of the analog output.
Protection typeIP20

Safety and protection - Test voltage

Test voltage (input IN 2.1/relay output; per EN 61010-1)5.4 kVAC ; 50 Hz; 5 s, 3.6 kVAC; 50 Hz; 1 min
Test voltage (input IN 2.1/relay output; per UL 61010-1)3.51 kVAC; 60 Hz; 1 min
Test voltage (input/supply and analog output/relay output)3.51 kVAC; 50 … 60 Hz; 1 min
Test voltage (supply/analog output)3.6 kVAC; 50 … 60 Hz; 1 min

Safety and protection - Insulation coordination (UL)

Overvoltage categoryIII
Pollution degree2
Insulation type (input/supply and analog output/relay output)Reinforced insulation (safe isolation)

Safety and protection - Insulation coordination

Overvoltage categoryIII
Pollution degree2
Insulation type (input IN 2.1/relay output)Reinforced insulation (safe isolation)
Insulation type (input/supply and analog output/relay output)Requirement: The N (GND 1) input must not be hazardous when active., Double insulation (impedance and basic insulation), Requirement: The N (GND 1) input is dangerous when active!

Connection data

Connection technologyPush-in CAGE CLAMP®
WAGO connectorpicoMAX® 5.0
Solid conductor0.2 … 2.5 mm² / 24 … 12 AWG
Fine-stranded conductor0.2 … 2.5 mm² / 24 … 12 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width22.5 mm / 0.886 inches
Height110 mm / 4.331 inches
Depth from upper-edge of DIN-rail107 mm / 4.213 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Fire load2.158 MJ
Weight128.7 g

Environmental requirements

Ambient temperature (operation)-40 … +70 °C
Ambient temperature (storage)-40 … +85 °C
Temperature range of connection cable≥ (Tambient + 25 K)
Temperature range of the connection cable (UL)95 °C
Relative humidity5 … 85 % (non-condensing)
Operating altitude (max.)2000 m

Standards and specifications

Conformity markingCE
EMC immunity to interferenceEN 61000-6-2; EN 61326-2-3
EMC emission of interferenceEN 61000-6-3; EN 61326-2-3
Standards/specificationsEN 61010-1, UL 61010-1, UL 61010-2-201

Commercial data

PU (SPU)1 pcs
Packaging typebag
Country of originDE
GTIN4055143907323
Customs tariff number85437090300

Product Classification

UNSPSC41113630
ETIM 9.0EC002476
ETIM 10.0EC002476
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.1303-86-2, 1317-36-8, 7439-92-1, 75980-60-8, 79-94-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts, Phosphine oxide, diphenyl(2,4,6-trimethylbenzoyl)-
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption6(c), 7(a), 7(c)-I, 7(c)-II
SCIP notification number (Austria)e9a0da3f-7ab8-4615-8bb8-51d84373ba4c
SCIP notification number (Belgium)cde42bc2-2ed6-4b3f-b95b-c988d14bf8db
SCIP notification number (Bulgaria)02ec92ad-0329-4305-b22b-9e24a0f958c9
SCIP notification number (Czech Republic)d096da26-d7f8-4d5e-becc-86e2fb93012f
SCIP notification number (Denmark)ea1432b2-fa84-46ab-8a5d-075664e979ef
SCIP notification number (Finland)711a69de-5cbd-429b-a6d3-8ffed1a1b9f3
SCIP notification number (France)7750255c-4551-444f-b3c6-a4edfe120427
SCIP notification number (Germany)f2d91d82-2ffe-4f8c-815a-b19f31daaf10
SCIP notification number (Hungary)118e1f7b-e544-475b-8dbf-0016c1a2f149
SCIP notification number (Italy)02841e02-dc41-4530-999f-a472b42b8822
SCIP notification number (Netherlands)b182a8b9-fbbe-43c7-a18e-99b519fe0e2f
SCIP notification number (Poland)f7f4ead4-ec70-41f8-88ec-eb9d615fea26
SCIP notification number (Romania)0237191f-9eb4-45db-8b80-7a562cc49da6
SCIP notification number (Sweden)7a289ca8-3605-43d8-9581-2947e0665a91

Customer Reviews