4 IO-Link interfaces per moduleEach interface can be configured as a standard input or outputSeamless integration in POWERLINKSupports all transfer rates

I…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 IO-Link interfaces per moduleEach interface can be configured as a standard input or outputSeamless integration in POWERLINKSupports all transfer rates

IO-Link is a standardized communication system for connecting intelligent sensors and actuators in an automation system. The standardization includes electrical connection data as well as a digital communication protocol, which is used by the sensors and actuators in the automation system for data exchange. An IO-Link system consists of an IO-Link master and one or more IO-Link devices, i.e. sensors and actuators. The IO-Link master makes the interface available for higher level control and controls communication with the connected IO-Link devices. An IO-Link device is an intelligent sensor or actuator. With regard to IO-Link, “intelligent” means that a device possesses a series number or parameter data (sensitivity, switching delays or characteristic curves), which can be written to or read via the IO-Link protocol.Process optimizationThe use of intelligent sensors and actuators contributes to process optimization. Process optimization means that downtimes should be kept as short as possible. These consist mainly of standstills due to errors and setup times. Integrated communication down to the IO-Link devices offers many advantages in error diagnostics. Errors are detected much faster than before. If a sensor or actuator must be replaced, lengthy configuration work is no longer necessary after the change thanks to a potentiometer, or a configuration tool and laptop. After changing the sensor/actuator, the parameters are automatically transferred to the sensor. This parameter download is not only beneficial when errors occur. It can also be used for changing parameters when a load change is performed. This shortens setup times, making product changes and small batches more economical.Integrating IO-Link into the X20 SystemIO-Link is integrated in the X20 system using this digital module. All 4 channels are IO-Link interfaces, but can also be used as standard inputs or outputs. The specified 3-wire connections can be ideally implemented thanks to the X20 connector system with 12 terminal points per module. All specified transfer rates are also supported.POWERLINK integrationIO-Link doesn’t stop at the I/O module. It must be integrated in the higher-level bus system to fully utilize the benefits. When using POWERLINK, access is made possible via device description files in XML format.

Specification

I/O module

IO-Link master with 4 IO-Link interfaces

B&R ID code

0xA38E

Status indicators

IO-Link, operating state, module status

Module run/error

Yes, using LED status indicator and software

C/Q status

Yes, using LED status indicator and software

Cable type

3-pin standard sensor cable

Cable length

Max. 20 m

Line capacitance

Max. 3 nF

Loop resistance

Max. 6 Ω

Bus

0.01 W

Internal I/O

1.6 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Voltage

I/O power supply minus voltage drop for short-circuit protection

Voltage drop for short-circuit protection at 0.3 A

Max. 1 VDC

Power consumption

Max. 9 W per interface

Short-circuit proof

Yes

COM1

4.8 kbaud

COM2

38.4 kbaud

COM3

230.4 kbaud

Max. connection capacity

47 nF (cable and device)

Max. load

100 Ω / 0.3 A

Data format

1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit

Bus level

24 VDC (active), 0 VDC (resting voltage)

Variant

Bipolar, positive and negative switching

Diagnostics

Output monitoring with 100 ns delay and internal protection of the semiconductor with 100 µs delay

Peak short-circuit current

<1.5 A

Residual voltage

<1.5 VDC at nominal current 0.2 A

Switching voltage

I/O power supply minus voltage drop for short-circuit protection and semiconductor switch

Voltage drop on semiconductor switch

Max. 1.5 VDC at 0.2 A

Switching frequency

Typ. 25 kHz
300 kHz in IO-Link master mode

0 → 1

<10 µs

1 → 0

<10 µs

Switch-on in the event of overload shutdown or short-circuit shutdown

Approx. 10 ms (depends on the module temperature)

Braking voltage when switching off inductive loads

Typ. 52 VDC

Nominal voltage

24 VDC

Nominal output current

0.2 A

Total nominal current

0.4 A

Output circuit

Sink or source

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads

Actuator power supply

24 VDC / Max. 0.3 A per interface (fused)

Hardware

100 ns

Software

Input circuit

Sink

Sensor power supply

24 VDC / Max. 0.3 A per interface (fused)

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Typ. 5 mA

Input resistance

Typ. 4.8 kΩ

Low

<8 VDC

High

>13 VDC

Electrical isolation

Bus isolated from IO-Link

IO-Link not isolated from IO-Link

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

0 to 55°C

Vertical mounting orientation

0 to 45°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.

Pitch