Fast delivery within 72 Hours

B&R X20cDO4633

4 digital outputsOutputs with integrated snubber circuitOutputs with 48 to 240 VACL switchingZero-crossing detectionPhase-angle controlOpen-circuit detection for each channelNegative half-waves can be…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

4 digital outputsOutputs with integrated snubber circuitOutputs with 48 to 240 VACL switchingZero-crossing detectionPhase-angle controlOpen-circuit detection for each channelNegative half-waves can be switched off50 Hz or 60 Hz2-wire connections240 V codingOSP modeFrequency mode

The module is a digital output module with phase-angle control that is equipped with 4 Triac outputs using 2-line connections. The supply (L and N) is fed directly to the module.

Specification

I/O module4 digital outputs 48 to 240 VAC for 2-wire connections
B&R ID code0xE67D
Status indicatorsI/O function per channel, operating state, module status
Module run/errorYes, using LED status indicator and software
OutputsYes, using LED status indicator
Bus0.6 W
Internal I/O
External I/O
Additional power dissipation caused by actuators (resistive) [W]+6.4
CEYes
UKCAYes
ATEXZone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X
ULcULus E115267 Industrial control equipment
HazLoccCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5
VariantTriac
CircuitL-switching
Nominal voltage48 to 240 VAC
Max. voltage264 VAC
Rated frequency47 to 63 Hz
Nominal output current1 A
Total nominal current4 A
Output current1.25 A
Summation current5 A
Connection type2-wire connections
Zero-crossing detectionYes
Minimum holding current IH15 mA
Leakage currentMax. 2 mA at 240 V at 50 Hz Max. 2.4 mA at 240 V at 60 Hz
Residual voltage (on-state voltage)1.6 V
Area5 to 95%
Resolution1%
Accuracy (60 to 240 VAC)<100 μs
Voltage monitoring L - NNo
Additional functionsOpen-circuit detection
Overvoltage protection between L and NYes
Channel - BusTested at 1500 VAC
Channel - Internal I/OTested at 2000 VAC
Channel - GroundTested at 1500 VAC
ExternalSee section “External fuses”.
InternalSnubber circuit (RC element) and varistor
Electrical isolationChannel isolated from bus and I/O power supply
HorizontalYes
VerticalYes
0 to 2000 mNo limitation
>2000 mNot permitted
Degree of protection per EN 60529IP20
Horizontal mounting orientation-25 to 60°C
Vertical mounting orientation-25 to 50°C
DeratingSee section “Derating”.
Starting temperatureYes, -40°C
Storage5 to 95%, non-condensing
Transport5 to 95%, non-condensing
OperationUp to 100%, condensing
NoteOrder 1x terminal block X20TB32 separately. Order 1x bus module X20cBM32 separately.
Pitch25+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20cDO4633”

Your email address will not be published. Required fields are marked *