Fast delivery within 72 Hours
B&R X20cBR9300
X2X Link bus receiverFeed for X2X Link and internal I/O supplyElectrical isolation of feed and X2X Link supplyRedundancy of X2X Link supply possible by operating multiple supply modules simultaneously…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
X2X Link bus receiverFeed for X2X Link and internal I/O supplyElectrical isolation of feed and X2X Link supplyRedundancy of X2X Link supply possible by operating multiple supply modules simultaneouslyOperation only on the slot to the far left
The bus receiver is used to connect the X20 System to the X2X Link. The module is equipped with a feed for the X2X Link as well as the internal I/O supply.
Specification
| Bus receiver |
X2X Link bus receiver with supply for I/O and bus |
|---|---|
| B&R ID code |
0xDD48 |
| Status indicators |
X2X bus function, overload, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Overload |
Yes, using LED status indicator and software |
| X2X bus function |
Yes, using LED status indicator |
| Power consumption for X2X Link power supply |
1.62 W |
| Internal I/O |
0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267Industrial control equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| Input voltage |
24 VDC -15% / +20% |
| Input current |
Max. 0.7 A |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
No |
| Nominal output power |
7 W |
| Parallel connection |
Yes |
| Redundant operation |
Yes |
| Overload characteristics |
Short-circuit proof, temporary overload |
| Nominal output voltage |
24 VDC |
| Behavior on short circuit |
Required line fuse |
| Permissible contact load |
10 A |
| Electrical isolation |
X2X Link supply isolated from X2X Link power supplyI/O supply not isolated from I/O power supply |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
See section "Derating". |
| Starting temperature |
Yes, -40°C |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
Up to 100%, condensing |
| Note |
Order 1x terminal block X20TB12 separately.Order 1x power supply bus module X20cBM01 separately |
| Pitch |
12.5+0.2 mm |