Fast delivery within 72 Hours

B&R 80VD100PS.C02X-01

Control for 1 servo motor1 resolver interface2 trigger inputsMotor holding brake connectionEnable input

ACOPOSmicro inverter module, X2X…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Control for 1 servo motor1 resolver interface2 trigger inputsMotor holding brake connectionEnable input

ACOPOSmicro inverter module, X2X POWERLINK interface, 1x resolver, 24-64 VDC ±25% power supply, 1 motor connection, 8 A continuous current, 2 digital inputs 24 VDC, sink, can be used as trigger inputs, 1 digital output 24 VDC, 1 A, order terminal blocks separately!

Specification

Inverter module

Connection for 1 servo motor with resolver

B&R ID code

0xAB6E

Status indicators

POWERLINK, operating state, module status, motor information

Module run/error

Yes, using LED status indicator and software

Module temperature / Cooling unit temperature

Yes, using software

Motor status

Yes, using LED status indicator and software

CPU - 24 VDC power supply

No

CPU - Power supply

Yes

CPU - Motor connection

Yes

CPU - Digital inputs

Yes

CPU - Trigger inputs

Yes

CPU - Enable inputs

Yes

CPU - Resolver interface

No

CPU - Motor holding brake

No

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Functional safety

Yes

UL

cULus E225616
Power conversion equipment

KC

Yes

Input voltage

24 VDC ±25%

Voltage monitoring

Yes

CPU

Max. 8 W

Inrush current

Max. 10 A

Idle (no motor powered)

0.5 W

Continuous power consumption

655 W

Switching frequency 5 kHz

[0.24×IM1² + 0.216×IM1 + 0.4] W

Switching frequency 10 kHz

[0.24×IM1² + 0.215×IM1 + 0.8] W

Switching frequency 20 kHz

[0.24×IM1² + 0.214×IM1 + 1.6] W

Switching frequency 40 kHz

[0.24×IM1² + 0.213×IM1 + 3.2] W

Inrush current limiting

Yes, PTC (min. 9 Ω), is bypassed during operation by means of relay contact.

Undervoltage cutoff

<18 VDC

Overvoltage cutoff

>95 VDC

Voltage measurement

Yes

Line protection

Must occur externally

Reverse polarity protection

Yes

Quantity

2

Nominal current

Up to 20 kHz: 8 ARMS / 11.3 APeak
At 40 kHz and greater than 45°C: 6.5 ARMS / 9.2 APeak

Max. current/motor

10.6 ARMS / 15 APeak

Max. current/module

15 APeak

Nominal switching frequency

5 kHz

Possible switching frequencies

5 / 10 / 20 / 40 kHz

Max. motor line length

25 m

Max. output frequency

598 Hz

Controller frequency

20 kHz

DC bus capacitance

940 µF

Axis 1

Yes

Axis 2

Nominal voltage

24 VDC

Continuous current per connection

1 A

Max. internal resistance

0.3 Ω

Resistive load

100 Hz

Inductive load

See section "Switching inductive loads".

Overload and short-circuit protection

Yes

Open-circuit monitoring

Yes

Undervoltage monitoring

Yes

Response threshold for open-circuit monitoring

<100 mA

Response threshold for undervoltage monitoring

≤23.5 V

Variant

Female RJ45 connector

Electrical isolation

Yes

Output voltage

3.4 Veff

Output current

Max. 50 mAeff

Frequency

10 kHz

Signal transmission

Differential signal

Angular position resolution

14 bits/rev

Short-circuit protection

Yes

Input impedance

10.4 kΩ – j 11.1 kΩ

BRX

0.5 (±10%)

BRT

0.5 (±10%) with limitations

Input current at nominal voltage

Approx. 7.5 mA

Input circuit

Sink

Low

<5 VDC

High

>15 VDC

Maximum

30 VDC

Insulation voltage between input and bus

500 Veff

Input capacitance

10 nF (Rev. < F0: 100 µF)

Additional functions

Can be used as trigger input

Nominal

24 VDC

Input resistance

Approx. 3.2 kΩ

Rising edge

[Instant recording] Typ. 52 µs

Falling edge

[Instant recording] Typ. 53 µs

Input - ACOPOS

Yes, 500 Veff

Input - Input

Yes, 500 Veff

Modulation compared to ground potential

Max. ±38 V

Horizontal

No

Vertical

Yes

Pollution degree per EN 61800-5-1

2 (non-conductive pollution)

Degree of protection per EN 60529

IP20

Operation

5 to 85%, non-condensing

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Note

Order terminal blocks and cables separately!

Mounting/Cooling

Screw mounting with heat spreader on mounting plate or cold-plate.

Width

65 mm

Height

134 mm

Depth

95 mm

Weight

700 g

Backplane

Always mount on conductive and earthed backplane.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R 80VD100PS.C02X-01”

Your email address will not be published. Required fields are marked *