Fast delivery within 72 Hours
Keyence NR-XTH08T
Environment-resistant temperature measurement unit. NR-XTH08T. Series: Multi-input Data Logger. Series code: NR-X series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Environment-resistant temperature measurement unit. NR-XTH08T. Series: Multi-input Data Logger. Series code: NR-X series
Specification
| Model Name |
Environment-resistant temperature measurement unit |
|---|---|
| Model Code |
NR-XTH08T |
| Series Title |
Multi-input Data Logger |
| Series Code |
NR-X series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117XT8T |
| Manuals URL |
https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117XT8T |
| Model |
NR-XTH08T |
| Input method |
Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system) |
| Number of input channels |
8*1 |
| Input connector type |
Miniature thermocouple connector (Universal type) |
| Measurement cycle |
Maximum sampling cycle: 10 ms (100 Hz) to 1 h |
| A/D converting system |
Delta-sigma method |
| A/D resolution |
24 bits |
| A/D integration time (noise filter) |
AUTO (Automatic configuration according to sampling cycle), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz) |
| Input type |
Thermocouple: K, J, E, T, R, S, B, N, C |
| Low pass filter |
PASS / 200 Hz / 20 Hz |
| Averaging |
Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average) |
| Reference contact compensation |
Switchable between internal and external |
| Reference contact compensation accuracy |
±0.5°C ±0.9°F (23°C ±3°C 73.4°F ±5.4°F at input terminal temperature equilibrium) |
| Maximum input rating |
±30 V*2 |
| Maximum allowable input ground voltage |
Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDCWet locations: 16 VAC and 22.6 Vpeak, or 35 VDC |
| Withstand voltage |
Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minuteBetween measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute |
| Input impedance |
10 MΩ or more |
| Input signal source resistance |
2 kΩ or less |
| Thermocouple burnout detection |
Switchable between ON/OFF, When ON: Approx. 10 μA current detection*3 |
| Measurable range |
K: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°FJ: −100 to +1200°C -148°F to +2192°F, −200 to −100°C -328°F to -148°FE: −100 to +1000°C -148°F to +1832°F, −200 to −100°C -328°F to -148°FT: −100 to +400°C -148°F to +752°F, −200 to −100°C -328°F to -148°FN: −100 to +1300°C -148°F to +2372°F, −200 to −100°C -328°F to -148°FC: 1500 to 2315°C 2732°F to 4199°F, 0 to 1500°C 32°F to 2732°FR: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FS: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FB: 400 to 600°C 752°F to 1112°F, 600 to 1820°C 1112°F to 3308°F |
| Measurement accuracy |
K: ±0.04% of rdg ±0.4°C ±0.7°F, ±0.43% of rdg ±0.1°C ±0.2°FJ: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.30% of rdg ±0.1°C ±0.2°FE: ±0.03% of rdg ±0.3°C ±0.5°F, ±0.27% of rdg ±0.1°C ±0.2°FT: ±0.4°C ±0.7°F, ±0.34% of rdg ±0.1°C ±0.2°FN: ±0.02% of rdg ±0.6°C ±2.1°F, ±0.63% of rdg ±0.1°C ±0.2°FC: ±0.10% of rdg ±0.2°C ±0.4°F, ±0.04% of rdg ±0.8°C ±1.4°FR: ±0.01% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°FS: ±0.02% of rdg ±1.2°C ±2.2°F, ±2.0°C ±3.6°FB: ±2.2°C ±4.0°F, ±1.6°C ±2.9°F*4 |
| Display resolution |
K: 0.05°C 0.09°FJ: 0.05°C 0.09°FE: 0.05°C 0.09°FT: 0.01°C 0.02°FN: 0.05°C 0.09°FC: 0.05°C 0.09°FR: 0.05°C 0.09°FS: 0.05°C 0.09°FB: 0.05°C 0.09°F |
| Buffer memory |
16M data*5 |
| Warm up time |
30 minutes or more |
| Common mode noise reduction ratio |
135 dB or more (up to 60 Hz DC) (typ.) *4 |
| Remote connection |
Dedicated environment-resistant remote unit input port × 1 (Remote IN), output port × 1 (Remote OUT)Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cableConnectable to multiple environment-resistant measurement units*6 |
| Synchronization accuracy between remote connection units |
±1 μs*7 |
| Power supply |
Supplied from NR-X100W master unit |
| Power consumption |
5.0 W max. |
| Surrounding air temperature |
−40 to +85°C -40°F to +185°F*8 |
| Operating ambient humidity |
Max. 100% RH*9 |
| Vibration resistance |
100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*10Equivalent to JIS D1601 Stage 45 (Class 1, Class 2, and Class 3; equivalent to Class B) automotive vibration standard |
| Shock resistance |
1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27) |
| Enclosure rating |
IP65/IP67 (IEC 60529)Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250)Indoor/outdoor use |
| Material |
Main unit case: Aluminum die-casting (coated) / PBT+PC / PC, Display: Reinforced glass,Connectors: Brass (chromate processing), Connector protection cap: PBT+PC |
| Weight |
Approx. 660 g 23.30 oz |

Reviews