Keyence GL-T11R

Safety Relay Terminal. GL-T11R. Series: Safety Light Curtain. Series code: GL-R series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Safety Relay Terminal. GL-T11R. Series: Safety Light Curtain. Series code: GL-R series

Specification

Model NameSafety Relay Terminal
Model CodeGL-T11R
Series TitleSafety Light Curtain
Series CodeGL-R series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR54488&dlModelId=PM_247T11R&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/safety/light-curtain/gl-r/downloads/?mode=cd&modelId=PM_247T11R
Manuals URLhttps://www.keyence.com/products/safety/light-curtain/gl-r/downloads/?mode=ma&modelId=PM_247T11R
ModelGL-T11R
Applicable modelGL-R Series
Relay output250 VAC 6 A 30 VDC 6 A (Resistance load)240 VAC 2 A (COSø=0.3) (Inductive load)24 VDC 1 A (COSø=0.3) (Inductive load)
Life-span100,000 cycles or more with 250 VAC 6 A resistance load (open/close frequency: 20 times/minute)100,000 cycles or more with 30 VDC 6 A resistance load (open/close frequency: 20 times/minute)500,000 cycles or more with 250 VAC 1 A resistance load (open/close frequency: 30 times/minute)500,000 cycles or more with 30 VDC 1 A resistance load (open/close frequency: 30 times/minute)AC15: 100,000 cycles or more with 240 VAC 2 A inductive load (open/close frequency: 20 times/minute, cosø = 0.3)DC13: 100,000 cycles or more with 24 VDC 1 A inductive load (open/close frequency: 20 times/minute, L/R = 48 ms)
Response time - ON→OFFGL-R +10 ms
Response time - OFF→ONGL-R +32 ms
External inputON voltage: [Power supply voltage – 5 V] to [Power supply voltage]OFF voltage: Open or 0 to 3 VShort circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
Power supply - Power voltage24 VDC ±10%, ripple (P-P) 10% or less, Class 2
Power supply - Current consumption.100 mA max. (24 VDC, GL-T11R only)
Approved standards - EMCEN61496-1, UL61496-1, IEC61496-1
Approved standardsEN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Approved standards - SafetyEN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE)EN ISO13849-1 : 2015 (Category4, PLe)UL508, EN50178
Environmental resistance - Enclosure ratingIP20 (IEC60529)Must be installed within a control panel rated at IP54 or higher.
Environmental resistance - Pollution degree2
Environmental resistance - Overvoltage categoryIII
Environmental resistance - Operating ambient temperature-10 to +55 °C 14 to 131 °F (No freezing)
Environmental resistance - Operating relative humidity15 to 85 % RH (No condensation)
Environmental resistance - Storage temperature-25 to +60 °C -13 to 140 °F (No freezing)
Environmental resistance - Storage relative humidity15 to 95 % RH
Environmental resistance - Altitude2,000 m or less
Environmental resistance - Vibration resistance10 to 55 Hz, Double amplitude 0.7 mm 0.03″, 20 sweeps in each of the X, Y, and Z directions
Environmental resistance - Shock resistance100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
MaterialPolycarbonate
WeightApprox. 310 g