Fast delivery within 72 Hours

Keyence FD-R80

Sensor Main Unit 65A/80A Type. FD-R80. Series: Clamp-on Flow Meter. Series code: FD-R series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Sensor Main Unit 65A/80A Type. FD-R80. Series: Clamp-on Flow Meter. Series code: FD-R series

Specification

Model NameSensor Main Unit 65A/80A Type
Model CodeFD-R80
Series TitleClamp-on Flow Meter
Series CodeFD-R series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57328&dlModelId=PM_160R80&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-r/downloads/?mode=cd&modelId=PM_160R80
Manuals URLhttps://www.keyence.com/products/process/flow/fd-r/downloads/?mode=ma&modelId=PM_160R80
ModelFD-R80
Supported pipe diameter2 1/2″ (65 A), ø64 to ø83 2.52″ to 3.27″3″ (80 A), ø83 to ø100 3.27″ to 3.94″
Supported pipe materialsMetal / resin*1
Supported fluidsVarious liquids (i.e. water, oils, chemicals)*1
Supported fluid temperature– 20 to + 120°C – 4.0 to + 248 °F (no freezing on the pipe surface)*2
Maximum rated flowRated flow velocity range: 5.0 m/sFlow rate range (Typical):2 1/2″ (65 A): 1000 L/min 260 gal/min 60 m3/ h)3″ (80 A): 1500 L/min 390 gal/min 90 m3 / h
Zero cut flow rateZero cut: 0.3 m/s (default)*3Flow rate (Typical): 90 L / min 24 gal / min 5.4 m3/h
Display methodDual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator
Display update cycleApprox. 3 Hz
Display resolution1 (L / min)
Response time0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)
Measurement accuracyBetween 20 and 100% of F.S. : ±2.0% of RD*4*5Between 6 and 20% of F.S. : ±0.4% of F.S. *4*5
Protection circuitPower supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output
Zero point error±0.5% of F.S.*4*6
HysteresisVariable
Flow unitsL / min, m3 / h, gal / min
Integrated flow unit display1 / 10 / 100 / 1000 / 10000 (L)
Pipe temperature measurement accuracy±3°C ±5.4°F (liquid temperature of – 20 to + 50°C, – 4 to + 122°F)±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F)(ambient operating temperature of 25°C 77°F)*4
Wiring specifications - Power supplyDC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)
Wiring specifications - I/OWhen using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block
Input/Output (Selectable) - Output (ch.1/ch.2)Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7
Input/Output (Selectable) - Analog output (ch.1/ch.2)Flow rate analog output / Temperature analog output and 4 – 20 mA / 0 – 20 mA (selectable), load resistance: 500 Ω or less*7
Input/Output (Selectable) - External input (ch.2)Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7
Rating - Power voltage20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC – 15% or + 10% (50 / 60 Hz)
Rating - Current consumptionWhen using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less
Environmental resistance - Enclosure ratingIP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)
Environmental resistance - Ambient temperature– 20 to + 60°C – 4.0 to 140 °F (no freezing)*2
Environmental resistance - Relative humidity5 to 90%RH (no condensation)
Environmental resistance - Vibration resistance10 to 55 Hz, compound amplitude 1.5 mm 0.06″, XYZ axes 2 hours for each axis
Environmental resistance - Shock resistance100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis
DimensionsMain unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60″ × 2.63″ × 2.78″
Material - Main unitBody: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent
Material - Unit rearRubber
Material - Upper/lower bracketSUS304
WeightMain unit: Approx. 1.0 kgUpper/lower bracket: Approx.2.0 kg (including sub unit)

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence FD-R80”

Your email address will not be published. Required fields are marked *