Fast delivery within 72 Hours
Pepperl Fuchs VBA-4E4A-G12-ZAJ/EA2L
AS-Interface sensor/actuator module. G12 flat module, 4 inputs (PNP) and 4 electronic outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
AS-Interface sensor/actuator module. G12 flat module, 4 inputs (PNP) and 4 electronic outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7. IO code7ID codeAID1 code7ID2 code7: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload. Auxiliary voltage (output): 24 V DC ± 15 % PELV. Rated operating voltage: 26.5 … 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA (without sensors) / max. 240 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral. Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC. Supply: from AS-Interface. Voltage: 21 … 31 V. Current loading capacity: ≤ 200 mA, overload and short-circuit protected. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 6 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 6 mA. Signal delay: < 1 ms (input/AS-Interface). Number/Type: 4 electronic outputs, PNP, overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX – 0.5 V). Current: 2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C). Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013: . Directive 2014/30/EU: EN 62026-2:2013. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005 EN 62026-2:2013. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 85 % , noncondensing. Altitude: ≤ 2000 m above MSL. Shock and impact resistance: 30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks. Vibration resistance: 0.75 mm 10 … 57 Hz , 5 g 57 … 150 Hz, 20 cycles. Pollution degree: 3. Degree of protection: IP67. Connection: Cable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector. Material: . HousingPBT: . Housing: PBT. Mass: 230 g. Tightening torque, cable gland: 0.4 Nm. Dimensions: . Height35 mmWidth57.4 mmLength151.6 mm: . Height: 35 mm. Width: 57.4 mm. Length: 151.6 mm. Mounting: Mounting plate
Specification
General specifications
| Node type | A/B node |
|---|---|
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V3.0 |
| Profile | S-7.A.7 |
| IO code7ID codeAID1 code7ID2 code7 | |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 7 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of sensor power supply or outputs |
|---|---|
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching status (output); 4 yellow/red LEDs Yellow: output activeRed: output overload |
Electrical specifications
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV |
|---|---|
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ≤ 40 mA (without sensors) / max. 240 mA |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
|---|---|
| Supply | from AS-Interface |
| Voltage | 21 ... 31 V |
| Current loading capacity | ≤ 200 mA, overload and short-circuit protected |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 6 mA | |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 6 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
Output
| Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
|---|---|
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 2 A per output6 A total (TB ≤ 40 °C)4 A total (TB ≤ 70 °C) |
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUEN 62026-2:2013 | |
| Directive 2014/30/EU | EN 62026-2:2013 |
Standard conformity
| Degree of protection | EN 60529:2000 |
|---|---|
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005 EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Altitude | ≤ 2000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks10 g, 16 ms in 6 spatial directions 1000 shocks |
| Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67 |
|---|---|
| Connection | Cable piercing methodflat cable yellow/flat cable blackinputs/outputs: M12 round connector |
| Material | |
| HousingPBT | |
| Housing | PBT |
| Mass | 230 g |
| Tightening torque, cable gland | 0.4 Nm |
| Dimensions | |
| Height35 mmWidth57.4 mmLength151.6 mm | |
| Height | 35 mm |
| Width | 57.4 mm |
| Length | 151.6 mm |
| Mounting | Mounting plate |

Reviews