Wago 284-624

Distribution terminal block, 284 Series, blueError-free electrical installations are guaranteed with this distribution terminal block (item number 284-624). Conductors can only be connected to this di…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Distribution terminal block, 284 Series, blueError-free electrical installations are guaranteed with this distribution terminal block (item number 284-624). Conductors can only be connected to this distribution terminal block if their strip length is between 12 and 14 mm . Distribution terminal blocks offer a space-saving way to distribute potentials with just a single terminal block. Their clever design means larger conductor cross-sections can be connected on one side and several smaller conductor cross-sections on the other. They are also ideal for potential collection in addition to potential distribution. Featuring conductor terminals along with CAGE CLAMP® as well as a screw connection, this product outperforms the competition. Our highly-rated and maintenance-free CAGE CLAMP® connection makes it easy to connect all types of conductors without having to prepare the conductor. For example, you don’t need to crimp ferrules. Screw-clamp connections can carry currents from a fraction of an ampere all the way up to several hundred amperes at low to moderate frequencies. Depending on the conductor type, this distribution terminal block is suitable for conductor cross sections ranging from 0.2 mm² to 10 mm² on one side and for conductor cross sections from 6 mm² to 35 mm² on the other side.This through rail-mount terminal block is operated with an operating tool.

Specification

Electrical data - Ratings per IEC/EN

Nominal voltage (III/3)800 V
Rated impulse withstand voltage (III / 3)8 kV
Rated current125 A
Legend (ratings)(III / 3) ≙ Overvoltage category III / Pollution degree 3

Electrical data - Power Loss

Power loss, per pole (potential)8.75 W
Rated current I<sub>N</sub> for power loss specification125 A
Resistance value for specified, current-dependent power loss0.001 Ω

Electrical data - General information

Wiring directionFront-/side-entry wiring

Connection data

Clamping units4
Total number of potentials1
Number of levels1

Connection data - Connection 1

Connection technologyCAGE CLAMP®
Number of connection points3
Actuation typeOperating tool
Connectable conductor materialsCopper
Solid conductor0.2 … 10 mm² / 24 … 8 AWG
Fine-stranded conductor0.2 … 10 mm² / 24 … 8 AWG
Strip length12 … 14 mm / 0.47 … 0.55 inches
Wiring directionFront-/side-entry wiring

Connection data - Connection 2

Connection technologyScrew connection
Number of connection points1
Solid conductor6 … 35 mm² / 10 … 2 AWG
Fine-stranded conductor6 … 35 mm² / 10 … 2 AWG

Physical data

Width17.5 mm / 0.689 inches
Height89 mm / 3.504 inches
Depth from upper-edge of DIN-rail39.5 mm / 1.555 inches

Mechanical data

Designhorizontal type
Mounting typeDIN-35 rail
Marking levelSide marking
Torque3.5 Nm

Material data

Note (material data)Information on material specifications can be found here
Colorblue
Material groupI
Insulation material (main housing)Polyamide (PA66)
Flammability class per UL94V0
Fire load0.625 MJ
Weight55.6 g

Environmental requirements

Processing temperature-35 … +85 °C
Continuous operating temperature-60 … +105 °C

Commercial data

PU (SPU)15 pcs
Packaging typebox
Country of originIN
GTIN4045454282578
Customs tariff number85369010000

Product Classification

UNSPSC39121410
eCl@ss 10.027-14-11-20
eCl@ss 9.027-14-11-20
ETIM 9.0EC000897
ETIM 10.0EC000897
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption