Pepperl Fuchs SK-IDM-Z1-x60-*
Supply module for IDM-Z1-*. Power supply for IDM-Z1-* handheld readers and base station, AC and DC power supplies for IDM-Z1-* handheld readers and base station, Enable operation in Zone 1/21, Sturdy…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Supply module for IDM-Z1-*. Power supply for IDM-Z1-* handheld readers and base station, AC and DC power supplies for IDM-Z1-* handheld readers and base station, Enable operation in Zone 1/21, Sturdy aluminum housing. Type: Supply Module. Power consumption: DC: 7.1 W AC: 16 W , 50 … 60 Hz. Operating voltage: DC: 24 V DC typical , 18 … 30 V DC voltage range AC: 230 V AC typical , 90 … 253 V AC voltage range. Interface type: depends on modelfield side (Ex e) : RS-232 / RS-422 or USB Connection side handheld readers and base station : RS-232 or USB. Electromagnetic compatibility: . Directive 2014/30/EUEN 61000-6-2:2005 + AC:2005 , EN 61000-6-4:2007 + A1:2011: . Directive 2014/30/EU: EN 61000-6-2:2005 + AC:2005 , EN 61000-6-4:2007 + A1:2011. Operating temperature: -25 … 60 °C (-13 … 140 °F). Storage temperature: -40 … 60 °C (-40 … 140 °F). Relative humidity: 95 % non-condensing. Degree of protection: IP64. Cable: power supply cable: 1.5 … 2.5 mm2 (24 AWG … 14 AWG), 3 pin data cable: 0.2 … 2.5 m2 (24 AWG … 14 AWG), 3 pin or 4 pin (depending on the model). LengthLmax. 15 m or 5 m, depending on the model: L. Length: max. 15 m or 5 m, depending on the model. Mass: approx. 3.1 kg. Dimensions: 140 mm x 250 mm x 56 mm (W x H x D). EU-type examination certificate: IBExU18ATEX1051 IECEx IBE 18.0010. Marking II 2G Ex eb q [ib IIC/IIB] IIC T4 Gb [exsign] II 2D Ex tb [ib] IIIC T135 °C Db: . Marking: II 2G Ex eb q [ib IIC/IIB] IIC T4 Gb [exsign] II 2D Ex tb [ib] IIIC T135 °C Db. Directive conformity: . Directive 2014/34/EUEN 60079-0:2018 EN 60079-11:2012 IEC 60079-31:2014 IEC 60079-5:2015 IEC 60079-7:2015: . Directive 2014/34/EU: EN 60079-0:2018 EN 60079-11:2012 IEC 60079-31:2014 IEC 60079-5:2015 IEC 60079-7:2015. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specification
General specifications
| Type | Supply Module |
|---|
Supply
| Power consumption | DC: 7.1 W AC: 16 W , 50 ... 60 Hz |
|---|
Electrical specifications
| Operating voltage | DC: 24 V DC typical , 18 ... 30 V DC voltage range AC: 230 V AC typical , 90 ... 253 V AC voltage range |
|---|
Interface
| Interface type | depends on modelfield side (Ex e) : RS-232 / RS-422 or USB Connection side handheld readers and base station : RS-232 or USB |
|---|
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUEN 61000-6-2:2005 + AC:2005 , EN 61000-6-4:2007 + A1:2011 | |
| Directive 2014/30/EU | EN 61000-6-2:2005 + AC:2005 , EN 61000-6-4:2007 + A1:2011 |
Ambient conditions
| Operating temperature | -25 ... 60 °C (-13 ... 140 °F) |
|---|---|
| Storage temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Relative humidity | 95 % non-condensing |
Mechanical specifications
| Degree of protection | IP64 |
|---|---|
| Cable | power supply cable: 1.5 ... 2.5 mm2 (24 AWG ... 14 AWG), 3 pin data cable: 0.2 ... 2.5 m2 (24 AWG ... 14 AWG), 3 pin or 4 pin (depending on the model) |
| LengthLmax. 15 m or 5 m, depending on the model | L |
| Length | max. 15 m or 5 m, depending on the model |
| Mass | approx. 3.1 kg |
| Dimensions | 140 mm x 250 mm x 56 mm (W x H x D) |
Data for application in connection with hazardous areas
| EU-type examination certificate | IBExU18ATEX1051 IECEx IBE 18.0010 |
|---|---|
| Marking II 2G Ex eb q [ib IIC/IIB] IIC T4 Gb [exsign] II 2D Ex tb [ib] IIIC T135 °C Db | |
| Marking | II 2G Ex eb q [ib IIC/IIB] IIC T4 Gb [exsign] II 2D Ex tb [ib] IIIC T135 °C Db |
| Directive conformity | |
| Directive 2014/34/EUEN 60079-0:2018 EN 60079-11:2012 IEC 60079-31:2014 IEC 60079-5:2015 IEC 60079-7:2015 | |
| Directive 2014/34/EU | EN 60079-0:2018 EN 60079-11:2012 IEC 60079-31:2014 IEC 60079-5:2015 IEC 60079-7:2015 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
|---|