Fast delivery within 72 Hours
Pepperl Fuchs NJ8-18GM-N-V1-Y36504
Inductive sensor. Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindri…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Inductive sensor. Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 8 mm. Installation: non-flush. Assured operating distance: 0 … 6.48 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 5 … 25 V. Switching frequency: 0 … 200 Hz. Hysteresis: 3 %. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 … 100 °C (-13 … 212 °F). Connection type: Connector plug. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Dimensions: . Length71 mmDiameter18 mm: . Length: 71 mm. Diameter: 18 mm. Use in the hazardous area: see instruction manuals
Specification
General specifications
| Switching function | Normally closed (NC) |
|---|---|
| Output type | NAMUR |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 6.48 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
|---|---|
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 200 Hz |
| Hysteresis | 3 % |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
Compliance with standards and directives
| Standard conformity | |
|---|---|
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
|---|---|
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
|---|
Mechanical specifications
| Connection type | Connector plug |
|---|---|
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Connector | |
| ThreadingM12 x 1Number of pins4 | |
| Threading | M12 x 1 |
| Number of pins | 4 |
| Dimensions | |
| Length71 mmDiameter18 mm | |
| Length | 71 mm |
| Diameter | 18 mm |
General information
| Use in the hazardous area | see instruction manuals |
|---|

Reviews
Clear filtersThere are no reviews yet.