Fast delivery within 72 Hours

Pepperl Fuchs NJ4-12GM50-WS-V12

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: non-flush, Output polarity: AC, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, th…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: non-flush, Output polarity: AC, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: AC, Connection type: Connector plug 1/2″-20 UN , 3-pin, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67. Switching function: Normally open (NO). Output type: Two-wire. Rated operating distance: 4 mm. Installation: non-flush. Output polarity: AC. Assured operating distance: 0 … 3.24 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.4. Reduction factor r304: 0.7. Output type: 2-wire. Operating voltage: 20 … 253 V. Switching frequency: 0 … 20 Hz. Voltage drop: typ. 4 V at 15 … 200 mAtyp. 6.5 V at 5 mA. Momentary current(20 ms, 0.1 Hz): 0 … 1200 mA. Operating current: 5 … 200 mA. Off-state current: typ. 0.7 mA. Time delay before availability: ≤ 30 ms. Switching state indicator: LED, yellow. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1. CSA approval: cCSAus Listed, General Purpose. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -25 … 70 °C (-13 … 158 °F). Connection type: Connector plug 1/2″-20 UN , 3-pin. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Dimensions: . Length50 mmDiameter12 mm: . Length: 50 mm. Diameter: 12 mm. Note: 1) In the temperature range below 0 °C, permissible operating voltage Ub 80…253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.. Scope of delivery: 2 self locking nuts in scope of delivery

Specification

General specifications

Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance4 mm
Installationnon-flush
Output polarityAC
Assured operating distance0 ... 3.24 mm
Reduction factor rAl0.4
Reduction factor rCu0.4
Reduction factor r3040.7
Output type2-wire

Nominal ratings

Operating voltage20 ... 253 V
Switching frequency0 ... 20 Hz
Voltage droptyp. 4 V at 15 ... 200 mAtyp. 6.5 V at 5 mA
Momentary current(20 ms, 0.1 Hz)0 ... 1200 mA
Operating current5 ... 200 mA
Off-state currenttyp. 0.7 mA
Time delay before availability≤ 30 ms
Switching state indicatorLED, yellow

Compliance with standards and directives

Standard conformity
StandardsEN IEC 60947-5-2
StandardsEN IEC 60947-5-2

Approvals and certificates

UL approvalcULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

Connection typeConnector plug 1/2"-20 UN , 3-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Dimensions
Length50 mmDiameter12 mm
Length50 mm
Diameter12 mm
Note1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.

General information

Scope of delivery2 self locking nuts in scope of delivery