Pepperl Fuchs NBN40-L2-A2-V1-M
Inductive sensor. Extended temperature range, Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont L</…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Inductive sensor. Extended temperature range, Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: VariKont L ®, Series: VariKont L ®, Operating voltage: 10 … 60 V DC, Type of voltage: DC, Ambient temperature: -40 … 85 °C (-40 … 185 °F) , Connection type: Connector plug, Housing material: PA-GF35, Degree of protection: IP69K, Threading: M12 x 1. Switching function: complementary. Output type: PNP. Rated operating distance: 40 mm. Installation: non-flush. Output polarity: DC. Assured operating distance: 0 … 32.4 mm. Actual operating distance: 36 … 44 mm. Reduction factor rAl: 0.34. Reduction factor rCu: 0.3. Reduction factor r304: 0.81. Reduction factor rSt37: 1. Reduction factor rBrass: 0.4. Output type: 4-wire. Operating voltage: 10 … 60 V DC. Switching frequency: 0 … 150 Hz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: pulsing. Voltage drop: ≤ 2 V. Operating current: 0 … 200 mA. Off-state current: 0 … 0.5 mA. No-load supply current: ≤ 20 mA. Operating voltage indicator: LED, green. Switching state indicator: LED, yellow. MTTFd: 680 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . StandardsEN IEC 60947-5-2Fire protectionrequirements of hazard level 1 to 3 (HL1 – HL3) according to DIN EN 45545-2 R26: . Standards: EN IEC 60947-5-2. Fire protection: requirements of hazard level 1 to 3 (HL1 – HL3) according to DIN EN 45545-2 R26. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA. CSA approval: cCSAus Listed, General Purpose. CCC approval: Certified by China Compulsory Certification (CCC). E1 Type approval: 10R-04. Ambient temperature: -40 … 85 °C (-40 … 185 °F). Connection type: Connector plug. Housing material: PA-GF35. Sensing face: PA-GF35. Degree of protection: IP69K. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Mass: 155 g. Dimensions: . Height40 mmWidth40 mmLength67 mm: . Height: 40 mm. Width: 40 mm. Length: 67 mm
Specification
General specifications
| Switching function | complementary |
|---|---|
| Output type | PNP |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Output polarity | DC |
| Assured operating distance | 0 ... 32.4 mm |
| Actual operating distance | 36 ... 44 mm |
| Reduction factor rAl | 0.34 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.81 |
| Reduction factor rSt37 | 1 |
| Reduction factor rBrass | 0.4 |
| Output type | 4-wire |
Nominal ratings
| Operating voltage | 10 ... 60 V DC |
|---|---|
| Switching frequency | 0 ... 150 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | pulsing |
| Voltage drop | ≤ 2 V |
| Operating current | 0 ... 200 mA |
| Off-state current | 0 ... 0.5 mA |
| No-load supply current | ≤ 20 mA |
| Operating voltage indicator | LED, green |
| Switching state indicator | LED, yellow |
Functional safety related parameters
| MTTFd | 680 a |
|---|---|
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
|---|---|
| StandardsEN IEC 60947-5-2Fire protectionrequirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26 | |
| Standards | EN IEC 60947-5-2 |
| Fire protection | requirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA |
|---|---|
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| E1 Type approval | 10R-04 |
Ambient conditions
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
|---|
Mechanical specifications
| Connection type | Connector plug |
|---|---|
| Housing material | PA-GF35 |
| Sensing face | PA-GF35 |
| Degree of protection | IP69K |
| Connector | |
| ThreadingM12 x 1Number of pins4 | |
| Threading | M12 x 1 |
| Number of pins | 4 |
| Mass | 155 g |
| Dimensions | |
| Height40 mmWidth40 mmLength67 mm | |
| Height | 40 mm |
| Width | 40 mm |
| Length | 67 mm |