Fast delivery within 72 Hours

Pepperl Fuchs LFL2-BK-U-PUR5-EMS

Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Float Switch. Switch element: microswitch, mercury-free, Limit value detection for fluids, Ball design: high buoyancy. Series: LFL2-**-U. Construction type: ball design. Contact loading: 250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load. Rated insulation voltage: 300 V. Pulse withstand voltage: 4 kV. Electrical life: ≥ 5 x 104 switching cycles. Low voltage: . Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009: . Directive 2014/35/EU: EN 60947-5-1:2004 + Cor.:2005 + A1:2009. Degree of protection: IEC 60529:2001. Description: microswitch with switching ball, change-over contact. Equipment architecture: This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.. CCC approval: Certified by China Compulsory Certification (CCC). Installation conditions: . Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.: . Installation instructions: range of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.. Process conditions: . Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3: . Process pressure (static pressure): ≤ 2 bar (29 psi) at 20 °C (68 °F). Density: ≥ 0.6 g/cm3. Ambient temperature: 5 … 70 °C (41 … 158 °F). Storage temperature: -25 … 70 °C (-13 … 158 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: IP68. Cable: . LengthL5 m: L. Length: 5 m. Material: float: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2). Switching point: switch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specification

General specifications

SeriesLFL2-**-U
Construction typeball design

Electrical specifications

Contact loading250 V AC/3 A; 150 V DC/0.25 A resistive load; 60 V DC/1 A resistive load
Rated insulation voltage300 V
Pulse withstand voltage4 kV
Electrical life≥ 5 x 104 switching cycles

Directive conformity

Low voltage
Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009
Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009

Conformity

Degree of protectionIEC 60529:2001

Application

Descriptionmicroswitch with switching ball, change-over contact

Function and system design

Equipment architectureThis device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.

Approvals and certificates

CCC approvalCertified by China Compulsory Certification (CCC)

Operating conditions

Installation conditions
Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.
Installation instructionsrange of application and minimum length between mounting and float:≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluidsmounting:The float switch is mounted by means of a counter weight or rods (e. g. float switch combination) from the top.The pivot of the cable should always be horizontal.
Process conditions
Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)Density≥ 0.6 g/cm3
Process pressure (static pressure)≤ 2 bar (29 psi) at 20 °C (68 °F)
Density≥ 0.6 g/cm3

Ambient conditions

Ambient temperature5 ... 70 °C (41 ... 158 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Altitude≤ 2000 m above MSL

Mechanical specifications

Degree of protectionIP68
Cable
LengthL5 mL
Length5 m

Mechanical construction

Materialfloat: PP (Polypropylene)cable: PUR, highly flexible (3 x 0.50 mm2)
Switching pointswitch angle, measured against the horizontal:- upper switch point 25° ±10°- lower switch point 6° ±6°