Fast delivery within 72 Hours
Keyence SI-F80U3
Spectroscopy Unit, Not Subject to Export Control. SI-F80U3. Series: Micro-head Spectral-interference Laser Displacement Meter. Series code: SI-F series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Spectroscopy Unit, Not Subject to Export Control. SI-F80U3. Series: Micro-head Spectral-interference Laser Displacement Meter. Series code: SI-F series
Specification
| Model Name |
Spectroscopy Unit, Not Subject to Export Control |
|---|---|
| Model Code |
SI-F80U3 |
| Series Title |
Micro-head Spectral-interference Laser Displacement Meter |
| Series Code |
SI-F series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/measure/spectral/si-f/downloads/?mode=cd&modelId=PM_216F8U3 |
| Manuals URL |
https://www.keyence.com/products/measure/spectral/si-f/downloads/?mode=ma&modelId=PM_216F8U3 |
| Model |
SI-F80U3 |
| Measurement range |
0.05 to 1.1 mm 0.002" to 0.04" *1 (Possible detection distance : 80 to 81.1 mm 3.15" to 3.19") |
| Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
| Spot diameter |
ø20 µm ø0.000787"*3 |
| Linearity |
±0.3 µm ±0.000012"*4 |
| Resolution |
0.25 µm 0.00000984"*5 |
| Sampling cycle |
200 µs |
| Light source for guide |
Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
| LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
| Temperature fluctuation |
0.01% of F.S./°C |
| Environmental resistance - Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
| Environmental resistance - Ambient temperature |
0 to +35 °C 32 to 95 °F |
| Environmental resistance - Relative humidity |
35 to 80 % RH (No condensation) |
| Environmental resistance - Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
| Material |
Polycarbonate |
| Weight |
Approx. 1 kg |

Reviews