Fast delivery within 72 Hours

Keyence SI-F1001

Controller. SI-F1001. Series: Micro-head Spectral-interference Laser Displacement Meter. Series code: SI-F series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Controller. SI-F1001. Series: Micro-head Spectral-interference Laser Displacement Meter. Series code: SI-F series

Specification

Model NameController
Model CodeSI-F1001
Series TitleMicro-head Spectral-interference Laser Displacement Meter
Series CodeSI-F series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR45583&dlModelId=PM_216F101&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/measure/spectral/si-f/downloads/?mode=cd&modelId=PM_216F101
Manuals URLhttps://www.keyence.com/products/measure/spectral/si-f/downloads/?mode=ma&modelId=PM_216F101
ModelSI-F1001*1
TypeMain Controller Separate type*2
No. of connectable spectrum units2
Display - Minimum display unit0.001 µm
Display - Display range±999.999 µm to ±9999.99 mm (7 settings selectable)
Display - Display cycle10 times/sec.
Terminal block - Laser remote interlock inputNon-voltage input*3
Terminal block - Analog voltage output±10 V x 2 outputs, Output impedance: 100 Ω*3
Terminal block - Analog current output4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*3
Terminal block - Alarm outputNPN open-collector output (N.C.)*3
Terminal block - General comparator outputNPN open-collector output*3
Expansion connector - TIMING2 inputNon-voltage input*3
Expansion connector - Program switch inputNon-voltage input x 3 inputs*3
Expansion connector - Alarm outputNPN open-collector output (N.C.)*3
Expansion connector - Comparator/ binary outputMeasured value data output (21 bits) OUT selectable NPN open-collector output*3
Expansion connectorNPN open-collector output*3
RS-232C interfaceMeasured data output and control input/output (Baud rate selectable to 115,200 bps max.)
USB interfaceUSB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible)
Ethernet interface100Base-TX/10Base-T
Major functions12 Out simultaneous measurementcalculation, average, filter, scaling measurement, measured value alarm, tolerance setting, auto-zero, data storage, light monitor, 8-program memory,interferometer mode, mask, connection of setting support software, etc.
Rating - Power voltage24 VDC ±10 %, Ripple (P-P) 10 % or less
Rating - Current consumptionOne head connected: 0.6 A or less. Six heads connected: 1.5 A or less.
Environmental resistance - Ambient temperature0 to +50 °C 32 to 122 °F*4
Environmental resistance - Relative humidity35 to 85 % RH (No condensation)
Environmental resistance - Vibration resistance10 to 55 Hz, Double amplitude 0.5 mm 0.02″, 2 hours in each of the X, Y, and Z directions
WeightApprox. 600 g