Fast delivery within 72 Hours
Keyence SC-S11
Main Unit. SC-S11. Series: Safety Controller. Series code: SC series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Main Unit. SC-S11. Series: Safety Controller. Series code: SC series
Specification
| Model Name |
Main Unit |
|---|---|
| Model Code |
SC-S11 |
| Series Title |
Safety Controller |
| Series Code |
SC series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/safety/safety-controller/sc/downloads/?mode=cd&modelId=PM_199S11 |
| Manuals URL |
https://www.keyence.com/products/safety/safety-controller/sc/downloads/?mode=ma&modelId=PM_199S11 |
| Model |
SC-S11 |
| Response time |
25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON) |
| Safety output (S-OUTPUT) - Output |
Two PNP outputs |
| Safety output (S-OUTPUT) - Max. load current |
500 mA |
| Safety output (S-OUTPUT) - Residual voltage (when ON) |
2.5 V maximum (with a load current of 500 mA) |
| Safety output (S-OUTPUT) - Leakage current |
1.2 mA maximum |
| Safety output (S-OUTPUT) - Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
| Safety output (S-OUTPUT) - Load wiring length |
30 m maximum |
| Safety input (S-INPUT, enable input) - Input type |
Contact output device connection or PNP output device connection |
| Safety input (S-INPUT, enable input) - Short-circuit current |
Approx 5mA |
| Safety input (S-INPUT, enable input) - ON/OFF voltage |
Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less |
| Safety input (S-INPUT, enable input) - Wiring length |
30 m maximum |
| Safety related input - Input type |
Non-voltage contact input (EDM input, reset input) |
| Safety related input - Short-circuit current |
EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input) |
| Safety related input - Wiring length |
30 m max. (EDM input, reset input) |
| Non-safety output - Output |
PNP/NPN totem pole output (auxiliary output, lockout output) |
| Non-safety output - Max. load current |
50mA (auxiliary output, lockout output) |
| Non-safety output - Load wiring length |
10 m maximum (auxiliary output, lockout output) |
| Non-safety input - Input type |
No-voltage contact input or PNP or NPN open-collector input (external off input) |
| Non-safety input - Short-circuit current |
Approx 5mA (external off input) |
| Non-safety input - ON/OFF voltage |
Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input) |
| Non-safety input - Wiring length |
10 m maximum (external off input) |
| Protection circuit |
Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection |
| Approved standards - EMC |
IEC 61496-1, EN61496-1, UL61496-1 |
| Approved standards |
EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A |
| Approved standards - Safety |
ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1 |
| Rating - Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
| Rating - Current consumption |
1.3 A (at maximum load) |
| Environmental resistance - Enclosure rating |
IP20 (IEC60529)Must be installed within a control panel rated at IP54 or higher. |
| Environmental resistance - Pollution degree |
2 (IEC60664/EN50178) |
| Environmental resistance - Overvoltage category |
2 (IEC60664, EN50178) |
| Environmental resistance - Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case |
| Environmental resistance - Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
| Environmental resistance - Operating relative humidity |
35 to 85 % RH (No condensation) |
| Environmental resistance - Storage temperature |
-20 to +65 °C -4 to 149 °F (No freezing) |
| Environmental resistance - Storage relative humidity |
35 to 85 % RH |
| Environmental resistance - Withstand voltage |
1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case |
| Environmental resistance - Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
| Environmental resistance - Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
| Material |
Polycarbonate (UL94-V2) |
| Weight |
160 g or less |

Reviews