Fast delivery within 72 Hours

Keyence NR-XHA08T

Environment-resistant analog measurement unit. NR-XHA08T. Series: Multi-input Data Logger. Series code: NR-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Environment-resistant analog measurement unit. NR-XHA08T. Series: Multi-input Data Logger. Series code: NR-X series

Specification

Model Name

Environment-resistant analog measurement unit

Model Code

NR-XHA08T

Series Title

Multi-input Data Logger

Series Code

NR-X series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117XH8T&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117XH8T

Manuals URL

https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117XH8T

Model

NR-XHA08T

Input method

Insulated single-end input, channels insulated from each other, input channels insulated from the case and other units (system)

Number of input channels

8*1

Input connector type

Dedicated 3-pin connector

Measurement cycle

Maximum sampling cycle: 100 μs (10 kHz) to 60 s

A/D converting system

Delta-sigma method

A/D resolution

24 bits

A/D integration time (noise filter)

AUTO (Automatic configuration according to sampling cycle), 25 μs (40 kHz), 208 μs (4.8 kHz), 2.5 ms (400 Hz), 16.7 ms (60 Hz), 20 ms (50 Hz), 100 ms (10 Hz)

Input frequency band

2 kHz (−3 dB or more)

Input type

Voltage input: ±60 V, ±20 V, ±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mVCurrent input: ±20 mA

Averaging

Switchable between ON/OFF, Averaging rate: 2 to 128 (moving average)

Input impedance - Voltage input ±2 V range or higher

1 MΩ ±2%

Input impedance - Voltage input ±1 V range or higher

10 MΩ ±2%

Input impedance - Current input

Approx. 100 Ω

Measurement range - ±60 V

Measurable range: −60.000 to +60.000 VMeasurement accuracy: ±0.05% of rdg ±8 mV *2Display resolution: 2 mV

Measurement range - ±20 V

Measurable range: −22.000 to +22.000 VMeasurement accuracy: ±0.05% of rdg ±4 mV *2Display resolution: 1 mV

Measurement range - ±10 V

Measurable range: −11.000 to +11.000 VMeasurement accuracy: ±0.05% of rdg ±2 mV *2Display resolution: 0.5 mV

Measurement range - ±5 V

Measurable range: −5.5000 to +5.5000 VMeasurement accuracy: ±0.05% of rdg ±0.8 mV *2Display resolution: 0.2 mV

Measurement range - ±2 V

Measurable range: −2.2000 to +2.2000 VMeasurement accuracy: ±0.05% of rdg ±0.4 mV *2Display resolution: 0.1 mV

Measurement range - ±1 V

Measurable range: −1.1000 to +1.1000 VMeasurement accuracy: ±0.05% of rdg ±0.2 mV *2Display resolution: 0.05 mV

Measurement range - ±500 mV

Measurable range: −550.00 to +550.00 mVMeasurement accuracy: ±0.05% of rdg ±0.08 mV *2Display resolution: 0.02 mV

Measurement range - ±200 mV

Measurable range: −220.00 to +220.00 mVMeasurement accuracy: ±0.05% of rdg ±0.04 mV *2Display resolution: 0.01 mV

Measurement range - ±100 mV

Measurable range: −110.000 to +110.000 mVMeasurement accuracy: ±0.05% of rdg ±0.02 mV *2Display resolution: 0.005 mV

Measurement range - ±20 mA

Measurable range: −22.000 to +22.000 mAMeasurement accuracy: ±0.08% of rdg ±0.004 mA *2Display resolution: 0.001 mA

Maximum input rating

Voltage input: ±60 V, Current input: ±30 mA

Maximum allowable input ground voltage

120 VAC and 170 Vpeak, or 120 VDC (when using NR-XHA08T protective grounding)The following applies when not using NR-XHA08T protective grounding.Dry locations: 30 VAC and 42.4 Vpeak, or 60 VDCWet locations: 16 VAC and 22.6 Vpeak, or 35 VDC

Withstand voltage

Between measurement input terminal and case/other units (system): 1000 VAC (50 Hz / 60 Hz) for 1 minuteBetween measurement input terminals: 1000 VAC (50 Hz / 60 Hz) for 1 minute

Buffer memory

16M data*3

Warm up time

30 minutes or more

Residual noise level

0.005% of F.S. (typ.) when A/D integration time is set to 20 ms (50 Hz) / 16.7 ms (60 Hz)0.05% of F.S. (typ.) when A/D integration time is set to 208 μs (4.8 kHz)*2

Common mode noise reduction ratio

105 dB or more (up to 60 Hz DC) (typ.)*2

Remote connection

Dedicated environment-resistant remote unit input port × 1 (Remote IN), Output port × 1 (Remote OUT)Connection to NR-X100W master data collection unit or other NR-XR01 remote units using environment-resistant unit cableConnectable to multiple environment-resistant measurement units*4

Synchronization accuracy between remote connection units

±1 μs*5

Power supply

Supplied from NR-X100W master unit

Power consumption

5.8 W or less

Surrounding air temperature

−40 to +85°C -40°F to +185°F*6

Operating ambient humidity

Max. 100% RH*7

Vibration resistance

100 m/s2 328.1 ft/s2; 5 to 2000 Hz; 2 hours in each of the X, Y, and Z directions (IEC 60068-2-6)*8Equivalent to JIS D1601 Stage 45 (Class 1, Class 2, and Class 3; equivalent to Class B) automotive vibration standard

Shock resistance

1000 m/s2 3280.8 ft/s2; 3 times in each of the X, Y, and Z directions (18 times in total) (IEC 60068-2-27)

Enclosure rating

IP65/IP67 (IEC 60529)Enclosure Type 4X (UL 50E, CSA C22.2 No. 94.2, NEMA 250)Indoor/outdoor use

Material

Main unit case: Aluminum die-casting (coated), Display: Reinforced glass, Connectors: Brass (chromate processing), Connector protection cap: PBT+PC

Weight

Approx. 690 g 24.36 oz