Fast delivery within 72 Hours
Keyence NR-X100W
Master data collection unit. NR-X100W. Series: Multi-input Data Logger. Series code: NR-X series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Master data collection unit. NR-X100W. Series: Multi-input Data Logger. Series code: NR-X series
Specification
| Model Name |
Master data collection unit |
|---|---|
| Model Code |
NR-X100W |
| Series Title |
Multi-input Data Logger |
| Series Code |
NR-X series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117X10W |
| Manuals URL |
https://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117X10W |
| Model |
NR-X100W |
| Main unit buffer memory capacity |
50M data*1 |
| Expansion memory |
SD card (SD/SDHC)*2 |
| PC interface - USB |
USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) |
| PC interface - Ethernet |
RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3 |
| PC interface - Wireless LAN |
Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3 |
| Network function |
FTP client function, FTP server function, SNTP client function |
| Display/operation |
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection |
| Expansion remote unit connection |
Dedicated remote connection connector × 2 (Remote OUT A port, B port)Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable) |
| Number of connectable measurement units - Master data collection unit group |
Max. 8 units*4 |
| Number of connectable measurement units - Total with remote units connected |
Max. 72 units*5 |
| Continuous acquisition speed - Master data collection unit group |
Max. 100 kHz for all acquisition channels *6 |
| Continuous acquisition speed - Total with remote units connected |
Max. 500 kHz for all acquisition channels *6*7 |
| Inter-unit synchronization - Between measurement units in the master data collection unit group |
±1 μs or less *8 |
| Time axis accuracy |
±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible |
| Synchronous trigger input (SYNC input) - Performance specifications |
• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode)• Non-voltage (contact/non-contact)/voltage input, Falling edge input• Not insulated from system bus |
| Synchronous trigger input (SYNC input) - Input specifications |
• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower• For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V |
| Control input - Common specifications |
• Input type: Bidirectional voltage input• Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA• Insulation between input and system bus (500 VDC/1 minute) |
| Control input - Individual specifications |
• External trigger input (TRG IN): Edge input• Acquisition start/stop input (START IN): Level input (only enabled in external control mode)• Auto-balance input (BAL): Edge input (only enabled in external control mode)• Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode) |
| Control output - Common specifications |
• Output format: Photo MOS relay output• Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less)• Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less• Insulation between output and system bus (500 VDC/1 minute) |
| Control output - Individual specifications |
• Trigger output (TRG OUT): N.O. output, one-shot output• System error output (SYS ERR): N.C. output• Alarm output (ALARM): N.O. output• Judgment output 1 to 4 (OUT1 to 4): N.O. output• Ready output (READY): N.O. output |
| Power supply |
• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less)• Battery operation possible when connected to the NR-XU15 Series battery power supply unit |
| Environmental resistance - Ambient temperature |
0 to +40°C 32°F to 104°F |
| Environmental resistance - Relative humidity |
10 to 85% RH (no condensation) |
| Weight |
Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) |

Reviews