Keyence LV-N11P
Amplifier, Cable, Main unit, PNP. LV-N11P. Series: Multi-Purpose Digital Laser Sensor. Series code: LV-N series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Amplifier, Cable, Main unit, PNP. LV-N11P. Series: Multi-Purpose Digital Laser Sensor. Series code: LV-N series
Specification
| Model Name |
Amplifier, Cable, Main unit, PNP |
|---|---|
| Model Code |
LV-N11P |
| Series Title |
Multi-Purpose Digital Laser Sensor |
| Series Code |
LV-N series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/sensor/laser/lv-n/downloads/?mode=cd&modelId=PM_153N11P |
| Manuals URL |
https://www.keyence.com/products/sensor/laser/lv-n/downloads/?mode=ma&modelId=PM_153N11P |
| Model |
LV-N11P |
| Type |
2 output |
| Output |
PNP |
| Cable/connector |
Cable |
| Main/Expansion unit |
Main unit |
| I/O - Control outputs |
2 output |
| I/O - External input |
1 input |
| I/O - Monitor output |
None |
| Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
| Timer function |
Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,Timer duration selectable: 1 ms to 9,999 ms,Maximum error against the setting value: ±10% max. |
| Control outputs |
PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less(Multiple connections) 1 output max: 20 mA or less |
| Response time |
80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 |
| Monitor output |
– |
| External input |
Input time 2 ms (ON)/20 ms (OFF) or more*2 |
| Number of interferenceprevention units |
Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3 |
| Case size |
H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1" |
| Unit expansion |
Up to 17 units can be connected in total (two-output type is treated as two units) |
| Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
| Rating - Power voltage |
24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5 |
| Rating - Powerconsumption |
Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)*7 |
| Environmental resistance - Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing)*8 |
| Environmental resistance - Relative humidity |
35 to 85 % RH (No condensation) |
| Environmental resistance - Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
| Environmental resistance - Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
| Material - Cable |
PVC |
| Material - Case |
Main unit and cover material: Polycarbonate |
| Weight |
Approx. 75 g |

Reviews