Sensor amplifier expansion unit. IX-H2050. Series: Image-Based Laser Sensor. Series code: IX series

Specification

Model Name

Sensor amplifier expansion unit

Model Code

IX-H2050

Series Title

Image-Based Laser Sensor

Series Code

IX series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57336&dlModelId=PM_263H205&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/sensor/laser/ix/downloads/?mode=cd&modelId=PM_263H205

Manuals URL

https://www.keyence.com/products/sensor/laser/ix/downloads/?mode=ma&modelId=PM_263H205

Model

IX-H2050

Main unit / expansion unit

Expansion unit

Display - Min. display unit

10 μm *1

Display

50 μm *1

Display - Display range

±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1

Tools - Scan mode

Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation,Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool*2

Tools - Line mode

Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation,Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools *3, Position adjustment: 1 tool, Tilt adjustment: 1 tool*2

Other functions - Common

Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR),Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching,Simultaneous main unit/expansion unit input, Mutual interference prevention, Security

Other functions - Scan mode

Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain),Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram,Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function

Other functions - Line mode

Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement,HOLD function, Alarm setting, Measurement method (Ave./Max./Min.), Laser sensitivity adjustment, Averaging filter, Median filter, X-axis median filter

Input - Input

Switchable between non-voltage input and voltage inputFor non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Input - Number of inputs

8 (IN1 to IN8)

Input - Function

IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functionsAssignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error)

Output - Output

Open collector output; NPN/PNP switchable, N.O./N.C. switchableFor open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or lessFor open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less

Output - Number of inputs

10 (OUT1 to OUT10)

Output - Function

Enable by assigning the optional functionsAssignable functions: Total judgment result (All OK/Any OK/NG), Run, Busy, Error, Position adjustment result, Tilt adjustment result, Result of the logical operation of each tool,Monochrome area / Height area tool result (OK/NG), Height / Step / Max./Min. / Calculation tool result (OK/NG/HIGH/LO), Alarm

Analog voltage output

Not available

Number of programs

32

Statistical information

Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1 *4

Detection history - Saved history

50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled)80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled)70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled)100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled) *5

Detection history

400 (FTP/SFTP client function: Enabled/High-resolution mode: -)500 (FTP/SFTP client function: Disabled/High-resolution mode: -) *5

Detection history - Save conditions

Selectable between NG only and All *5

Image data transmission (FTP/SFTP client function) - Destination

FTP/SFTP server

Image data transmission (FTP/SFTP client function) - Method

Selectable between bmp, jpeg, and txt

Image data transmission (FTP/SFTP client function) - Conditions

4 conditionsSelectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG)

Ethernet - Standard

Not available *6

Interface compatibility

CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *7

Number of connectible units

Main units: 1, Expansion units: 1, Communication units (DL): 1

Ratings - Power voltage

Supplied from main unit

Ratings - Current consumption

Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *8

Environmental resistance - Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Environmental resistance - Relative humidity

35 to 85% RH (No condensation)

Material

Main unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA /Head connector: Zinc + Ni plating, PA / Ethernet connector: Copper alloy + Ni plating / Rear heat sink:Aluminum / Main unit rear DIN rail fixing tab: POM / Nameplate: PC

Weight

Approx. 190 g