Fast delivery within 72 Hours
Keyence IX-150
Sensor Head 150 mm. IX-150. Series: Image-Based Laser Sensor. Series code: IX series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Sensor Head 150 mm. IX-150. Series: Image-Based Laser Sensor. Series code: IX series
Specification
| Model Name |
Sensor Head 150 mm |
|---|---|
| Model Code |
IX-150 |
| Series Title |
Image-Based Laser Sensor |
| Series Code |
IX series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/sensor/laser/ix/downloads/?mode=cd&modelId=PM_263150 |
| Manuals URL |
https://www.keyence.com/products/sensor/laser/ix/downloads/?mode=ma&modelId=PM_263150 |
| Model |
IX-150 |
| Reference distance |
150 mm 5.91" |
| Measuring distance |
100 to 200 mm 3.94" to 7.87" |
| Detection area - Scan mode |
Measuring distance of 100 mm 3.94": 56.5 × 42.0 mm 2.22" × 1.65"Measuring distance of 150 mm 5.91": 82.5 × 61.5 mm 3.25" × 2.42"Measuring distance of 200 mm 7.87": 108.5 × 81.0 mm 4.27" × 3.19"(X direction) × (Y direction) *1 |
| Detection area - Line mode |
Measuring distance of 100 mm 3.94": 56.5 mm 2.22"Measuring distance of 150 mm 5.91": 82.5 mm 3.25"Measuring distance of 200 mm 7.87": 108.5 mm 4.27"(X direction) *1 |
| Laser Light source - Light source |
660 nm (visible light) wavelength red semiconductor laser |
| Laser Light source - Laser class |
Class II laser product (FDA [CDRH] Part 1040.10), Class 2 laser product (IEC 60825-1: 2014) |
| Laser Light source - Output |
0.95 mW (FDA [CDRH] Part 1040.10), 1.6 mW (IEC 60825-1: 2014) |
| Height(Z direction) - Minimum detectable object size |
ø1.7 mm ø0.0669" *2 |
| Height(Z direction) |
ø0.9 mm ø0.0354" *3 |
| Height(Z direction) - Repeatability |
50 μm *6 |
| Width(X direction) |
0.5 mm 0.0197" *7 |
| Estimated detection |
(When measuring the height between two points, the minimum step difference is as follows.IX-055: 100 μm / IX-080: 200 μm / IX-150: 500 μm / IX-360: 1000 μm / IX-360W: 1000 μm) *6 |
| Sampling cycle - Scan mode |
120 ms (min.) (typical) |
| Sampling cycle - Line mode |
6 ms / 11 ms (selectable) |
| Image receiving element |
Monochrome CMOS image sensor |
| Image capture lighting - Light source |
Red LED |
| Image capture lighting - Lighting method |
Pulse lighting |
| Temperature characteristics |
0.04% of F.S./°C *8 |
| Environmental resistance - Enclosure rating |
IP67 |
| Environmental resistance - Ambient light |
Incandescent lamp, 5000 lux or less *9 |
| Environmental resistance - Ambient temperature |
0 to +45°C 32 to 113°F (No freezing) *10 |
| Environmental resistance - Relative humidity |
35 to 85% RH (No condensation) |
| Environmental resistance - Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions |
| Environmental resistance - Shock resistance |
500 m/s2 1640'/s2, 3 times in each of the 3 directions |
| Material |
Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector: Zinc die-casting |
| Weight |
Approx. 190 g |

Reviews
Clear filtersThere are no reviews yet.