Keyence GS-71P10

Power-to-lock Standard type PNP Standard cable 10 m. GS-71P10. Series: Safety Interlock Switches. Series code: GS series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Power-to-lock Standard type PNP Standard cable 10 m. GS-71P10. Series: Safety Interlock Switches. Series code: GS series

Specification

Model Name

Power-to-lock Standard type PNP Standard cable 10 m

Model Code

GS-71P10

Series Title

Safety Interlock Switches

Series Code

GS series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57337&dlModelId=PM_2671P10&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/safety/safety-interlock-switches/gs/downloads/?mode=cd&modelId=PM_2671P10

Manuals URL

https://www.keyence.com/products/safety/safety-interlock-switches/gs/downloads/?mode=ma&modelId=PM_2671P10

Model

GS-71P10

Lock type

Power-to-lock type

Type

Standard type

Response time - Lock

320 ms*1*2

Response time

220 ms*1*2*3

Lock - Locking force (Fzh)

Min. 2,000 N

Lock - Alignment tolerance of lock

±2 mm ±0.08"

Lock - Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Lock - Acceptable operation frequency

1 Hz*4

Lock - Door radius

Min. 250 mm 9.84"

Lock - Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output) - Output

Transistor outputs × 2

Control output (OSSD output) - Max. load current

Max. 150 mA

Control output (OSSD output) - Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

Control output (OSSD output) - OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Control output (OSSD output) - Leakage current

Max. 0.5 mA

Control output (OSSD output) - Max. capacitive load

2.2 µF

Control output (OSSD output) - Load wiring resistance

Max. 2.5 Ω

External input (Short-circuit current) - Safety input

Approx.1.5 mA × 2

External input (Short-circuit current) - Reset/EDM input

External input (Short-circuit current) - Lock control input

Approx. 2.5 mA × 1

External input (Short-circuit current) - OSSD operation switching input

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)EN 62061, IEC62061(SIL CL2/SIL CL3)EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)EN ISO14119(Type4)IEC 60947-5-3, EN 60947-5-3UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply - Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power supply - Power consumption

3.4 W*6

Environmental resistance - Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),Enclosure Type 3/4X/12/13 (NEMA250)

Environmental resistance - Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Environmental resistance - Operating relative humidity

5% to 95%RH

Environmental resistance - Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Environmental resistance - Storage relative humidity

5% to 95%RH

Environmental resistance - Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Environmental resistance - Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material - Sensor main unit

SUS304, PPS, PBT, PAR, PA66, NBR

Material

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Material - Actuator

PPS, PBT, NBR

Weight

Approx. 770 g