Fast delivery within 72 Hours
Keyence GS-11N5
Non-contact type Standard type NPN Standard cable 5 m. GS-11N5. Series: Safety Interlock Switches. Series code: GS series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Non-contact type Standard type NPN Standard cable 5 m. GS-11N5. Series: Safety Interlock Switches. Series code: GS series
Specification
| Model Name |
Non-contact type Standard type NPN Standard cable 5 m |
|---|---|
| Model Code |
GS-11N5 |
| Series Title |
Safety Interlock Switches |
| Series Code |
GS series |
| Data Sheet URL | |
| CAD URL | |
| Manuals URL | |
| Model |
GS-11N5 |
| Type |
Standard type |
| Operating distance - Front |
10 mm 0.39" |
| Operating distance |
18 mm 0.71" |
| Operating distance - Side |
6 mm 0.24" |
| Response time - Detection |
20 ms + 2 ms × (number of units cascaded -1)*1 |
| Response time |
30 ms + 25 ms × (number of units cascaded -1)*1 |
| Door operation |
3 Hz |
| Cascading - Standard |
Max. 30 units |
| Cascading - Using Y-shaped connector |
– |
| Control output (OSSD output) - Output |
Transistor outputs × 2 |
| Control output (OSSD output) - Max. load current |
Max. 100 mA |
| Control output (OSSD output) - Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
| Control output (OSSD output) - OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
| Control output (OSSD output) - Leakage current |
Max. 500 µA |
| Control output (OSSD output) - Max. capacitive load |
2.2 µF |
| Control output (OSSD output) - Load wiring resistance |
Max.2.5Ω |
| AUX (Non-safety related output) - Output |
Transistor output |
| AUX (Non-safety related output) - Number of outputs |
1 |
| AUX (Non-safety related output) - Max. load current |
50 mA |
| AUX (Non-safety related output) - Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
| External input (Short-circuit current) - Safety input |
Approx. 1.5 mA × 2 |
| External input (Short-circuit current) - Reset/EDM input |
– |
| Applicable Standards (Safety) |
EN 61508, IEC 61508 (SIL3)EN 6206, IEC62061 (SIL CL3)EN ISO13849-1: 2015 (PLe, Category 4)EN ISO14119 (Type4)IEC 60947-5-3, EN 60947-5-3UL 61010-1, CAN/CSA-C22.2 No.61010-1 |
| Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
| Power supply - Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
| Power supply - Power consumption |
0.8 W |
| Environmental resistance - Enclosure rating |
IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) |
| Environmental resistance - Operating ambient temperature |
-20°C to +55°C -4°F to 131°F (No freezing) |
| Environmental resistance - Operating relative humidity |
5% to 95%RH |
| Environmental resistance - Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*2 |
| Environmental resistance - Storage relative humidity |
5% to 95%RH |
| Environmental resistance - Vibration resistance |
10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
| Environmental resistance - Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
| Material - Sensor main unit |
Zinc die cast (Nickel chrome plating), PBT, PAR |
| Material |
PVC |
| Material - Actuator |
SUS430, SUS304, PBT |
| Weight |
Approx. 270 g |