Fast delivery within 72 Hours
Keyence GP-M400
Main Unit, Positive-pressure Type, 40 MPa. GP-M400. Series: Heavy Duty Type Digital Pressure Sensors. Series code: GP-M series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Main Unit, Positive-pressure Type, 40 MPa. GP-M400. Series: Heavy Duty Type Digital Pressure Sensors. Series code: GP-M series
Specification
| Model Name |
Main Unit, Positive-pressure Type, 40 MPa |
|---|---|
| Model Code |
GP-M400 |
| Series Title |
Heavy Duty Type Digital Pressure Sensors |
| Series Code |
GP-M series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/process/pressure/gp-m/downloads/?mode=cd&modelId=PM_240M400 |
| Manuals URL |
https://www.keyence.com/products/process/pressure/gp-m/downloads/?mode=ma&modelId=PM_240M400 |
| Model |
GP-M400 |
| Rated pressure |
0 to+5802 PSI(0 to+40 MPa) |
| Possible display range |
-580 to+6382 PSI(-4.00 to+44.00 MPa) |
| Zero-cut pressure value |
±0.5% of F.S. |
| Burst pressure |
14504 PSI (100 MPa) |
| Display resolution - kPa |
None |
| Display resolution - MPa |
0.01 |
| Display resolution - PSI |
1 |
| Display resolution - bar |
0.1 |
| Fluid type |
Liquid that will not corrode the liquid contact part |
| Type of pressure |
Gage pressure |
| Precision |
±1.0% of F.S. or less*1 |
| Repeatability |
±0.3% of F.S. or less*2 |
| Temperature characteristics |
±0.6% of F.S./10°C 50°F |
| Connection port |
G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) |
| Box rotation angle |
Maximum 330° |
| Medium temperature |
-20 to +100°C -4°F to +212°F (no freezing/condensation)*3 |
| Power voltage |
10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS |
| Current consumption |
50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 |
| Display method |
4 column, digital LED, red/Vertical inversion display possible |
| Operation display light |
Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) |
| Hysteresis |
During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)During window mode: fixed (0.5% of F.S.) |
| Response - Control output |
Selectable from 3 to 5000 ms |
| Response - Analog output |
As above + 2 ms (90% response) |
| Output - Output 1 control output |
NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)Main unit residual voltage 1 V max, N.O./N.C. selectable |
| Output |
4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5 |
| Environmental resistance - Enclosure rating |
IP67 |
| Environmental resistance - Pressure resistance |
50 MPa (500 bar) |
| Environmental resistance - Ambient temperature |
-20 to +80 °C -4 to 176 °F (No freezing and no condensation) |
| Environmental resistance - Relative humidity |
35 to 85 % RH (No condensation) |
| Environmental resistance - Vibration resistance |
IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis) |
| Environmental resistance - Shock resistance |
IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) |
| Materialproperties - Wetted part |
Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
| Materialproperties - Other parts |
Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU |
| Applicable cable |
M12 connector 4 pin |
| Weight |
Approx. 150 g |

Reviews
Clear filtersThere are no reviews yet.