Fast delivery within 72 Hours
Keyence GC-S1R
Safety relay output unit. GC-S1R. Series: Safety Controller. Series code: GC series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Safety relay output unit. GC-S1R. Series: Safety Controller. Series code: GC series
Specification
| Model Name |
Safety relay output unit |
|---|---|
| Model Code |
GC-S1R |
| Series Title |
Safety Controller |
| Series Code |
GC series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=cd&modelId=PM_269S1R |
| Manuals URL |
https://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=ma&modelId=PM_269S1R |
| Model |
GC-S1R |
| Input/output points - Safety inputs |
– |
| Input/output points - Safety relay output |
1 (3a) |
| Input/output points - AUX outputs |
– |
| Safety relay output specifications - Output type |
Relay (3a) (Externally-protected outputs)*1 |
| Safety relay output specifications - Rated load (resistance load) |
250 VAC 6A / 30 VDC 6A*2 |
| Safety relay output specifications - Rated load (inductive load) |
240 VAC 2A (AC-15) / 24 VDC 1A (DC-13) |
| Safety relay output specifications - Relay output mechanical life |
Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 timesResistance load (250 VAC 1A/30 VDC 1 A): Min. 500,000 timesInductive load (AC-15: 240 VAC 2 A): Min. 100,000 times (cosø = 0.3)Inductive load (DC-13: 24 VDC 1 A): Min. 100,000 times (L/R = 48 ms) |
| Safety relay output specifications - Maximum cable length |
Max. 100 m 328.1' |
| Safety relay output specifications - B10d |
With rated load: 400,000With low load: 2,000,000 |
| Test output specifications - Output type |
– |
| Applicable standards - EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A |
| Applicable standards - Safety |
IEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998 |
| Dimensions |
39.6×95×90 mm 1.56"×3.74"×3.54" (W×D×H) |
| Power supply - Power voltage |
– |
| Power supply - Power consumption |
Max. 80 mA |
| Environmental resistance - Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
| Environmental resistance - Relative humidity |
5 to 85% (No condensation) |
| Environmental resistance - Storage temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
| Environmental resistance - Operating altitude |
Max. 2000 m 6561.7' |
| Environmental resistance - Overvoltage category |
II (III for relay output part) |
| Environmental resistance - Pollution degree |
2 |
| Environmental resistance - Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14"Frequency: 9 to 150 Hz, Acceleration: 10 m/s210 times each in X, Y, Z directions |
| Environmental resistance - Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
| Material |
Polycarbonate |
| Weight |
Approx. 180 g |

Reviews