Keyence FD-G125
Clamp-On Gas Flow Meter DN 100A/125A. FD-G125. Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Clamp-On Gas Flow Meter DN 100A/125A. FD-G125. Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Specification
| Model Name |
Clamp-On Gas Flow Meter DN 100A/125A |
|---|---|
| Model Code |
FD-G125 |
| Series Title |
Clamp-On Gas Flow Meter |
| Series Code |
FD-G series |
| Data Sheet URL | |
| CAD URL |
https://www.keyence.com/products/process/flow/fd-g/downloads/?mode=cd&modelId=PM_160G125 |
| Manuals URL |
https://www.keyence.com/products/process/flow/fd-g/downloads/?mode=ma&modelId=PM_160G125 |
| Model |
FD-G125 |
| Pipe size - DN (Diameter Nominal) |
100 A, 125 A |
| Pipe size - NPS (Nominal Pipe Size) |
4", 5" |
| Pipe size - Outer diameter of pipe |
ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67" |
| Pipe size - Pipe thickness |
3.1 to 6.8 mm 0.122" to 0.27" |
| Supported pipe materials |
Iron, steel, stainless steel |
| Supported fluids |
Air, Nitrogen, other gases*1 |
| Fluid temperature |
0 to 60ºC 32 to 140 °F |
| Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
| Rated velocity of flow range |
Up to 15 m/s |
| Actual flow rate range (typical) - m3/h |
Pipe size 100 A: 470.0Pipe size 125 A: 720.0 |
| Actual flow rate range (typical) - L/min |
Pipe size 100 A: 7800Pipe size 125 A: 12000 |
| Actual flow rate range (typical) - CFM |
Pipe size 100 A: 280.00Pipe size 125 A: 420.00 |
| Standard flow rate range (typical) [CFM] - 20°C 68°F 60 psi 0.41 MPa |
Pipe size 100 A: 1326.34Pipe size 125 A: 1989.51 |
| Standard flow rate range (typical) [CFM] - 20°C 68°F 80 psi 0.55 MPa |
Pipe size 100 A: 1681.49Pipe size 125 A: 2522.23 |
| Standard flow rate range (typical) [CFM] - 20°C 68°F 100 psi 0.69 MPa |
Pipe size 100 A: 2036.63Pipe size 125 A: 3054.95 |
| Standard flow rate range (typical) [CFM] - 20°C 68°F 120 psi 0.83 MPa |
Pipe size 100 A: 2391.78Pipe size 125 A: 3587.67 |
| Display |
QVGA 2.2" LCD color monitor |
| Display update cycle |
Approx. 3 Hz |
| Display resolution - Instantaneous flow rate |
0.1 m3/h, 1 L/min, 0.1 CFM |
| Display resolution - Consumption/leakage amount |
0.1 m3, 1 L, 1 CF |
| Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
| Measurement accuracy - Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
| Measurement accuracy - Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
| Zero point error |
±0.15% of F.S.*2*6 |
| Static leakage repeatability |
±1.0% of RD*4*7 |
| Hysteresis |
Variable |
| Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
| I/O wiring connection port |
M12 4-pin connector (male) |
| Detection mode (switchable) - ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
| Detection mode (switchable) - ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
| Standard I/O (switchable) - Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
| Standard I/O (switchable) - Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
| Standard I/O (switchable) - External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
| Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
| Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
| Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
| Communication interface - USB |
USB 2.0 |
| Communication interface - Ethernet |
IEEE 802.3u (100BASE-TX) |
| Communication interface |
100 Mbps |
| Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
| Recording capacity - Consumption amount/ leakage amount |
Approx. 5 years |
| Recording capacity - Events |
100 |
| Power supply - Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
| Power supply - Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded) |
| Environmental resistance - Enclosure rating |
IP65/67 (IEC 60529)*10 |
| Environmental resistance - Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
| Environmental resistance - Relative humidity |
5 to 85%RH (no condensation) |
| Environmental resistance - Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
| Environmental resistance - Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
| Material - Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
| Material - Detection head |
Body: PPS/SUS304, rear surface: rubber |
| Material - Mounting/damping bracket |
SUS304 |
| Weight |
Approx. 2.7 kg |