Keyence EX-V02P

Amplifier Unit PNP. EX-V02P. Series: High-speed, High-Accuracy Digital Displacement Inductive Sensor. Series code: EX-V series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Amplifier Unit PNP. EX-V02P. Series: High-speed, High-Accuracy Digital Displacement Inductive Sensor. Series code: EX-V series

Specification

Model Name

Amplifier Unit PNP

Model Code

EX-V02P

Series Title

High-speed, High-Accuracy Digital Displacement Inductive Sensor

Series Code

EX-V series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR_ex_v&dlModelId=PM_088V02P&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/sensor/proximity/ex-v/downloads/?mode=cd&modelId=PM_088V02P

Manuals URL

https://www.keyence.com/products/sensor/proximity/ex-v/downloads/?mode=ma&modelId=PM_088V02P

Model

EX-V02P*1

Type

Amplifier Unit PNP

Shape

M10 x 18 mm 0.71" Threaded

Measuring range

0 to 2 mm 0.08"

Display range

-19,999 to +19,999

Linearity

±0.3% of F.S.

Resolution (No. of averagingmeasurements: 64)

0.4 μm

Sampling rate

40,000 samplings max./sec. *2

Display speed

20 times/sec.

Display power

7-segment 2-color LED

Over-range alarm

±FFFF is displayed.

Control input

PNP: Applied voltage; 10 to 30 V

Control output - Setting method

Upper/lower 2-level setting x 4 patterns (selectable)

Control output - Signal

PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)

Control output - Response time

0.075 ms (at maximum speed)

Control output - OFF-delay time

60 ms

Strobe output

PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)

Alarm output

PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)

Analog output voltage - Output voltage

±5V

Analog output voltage - Impedance

100 Ω

Analog output voltage - Response time

0.075 ms (at maximum speed)

Temperature characteristics

0.07% of F.S./°C *3

Major functions

FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.

Rating - Power voltage

24 VDC ±10%, Ripple (P-P): 10% max.

Rating - Current consumption

240 mA max.

Environmental resistance - Ambient temperature

0 to 50°C 32 to 122 °F

Environmental resistance - Relative humidity

35 to 85%, No condensation

Environmental resistance - Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 235 g