Reliable, non-contact temperature measurement of objects with very high temperatures
For applications in the steel and glass industries
Intuitive setting of analogue output and switching output via pushbutton
Clearly visible display for showing the current temperature
Robust housing and scratch-resistant precision lens for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range250...1600 °C
482...2912 °F
250...1600 °C482...2912 °F
Communication interfaceIO-Link

Application

Applicationtempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 50
Min. insulation resistance[MΩ] [MΩ]100; (50 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Inputs

Test inputtype 3 (IEC 61131-2)

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]500
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Short-circuit proofyes
Overload protectionyes

Detection zone

Wave length range[µm] [µm]1...1.7

Measuring/setting range

Measuring range250...1600 °C
482...2912 °F
250...1600 °C482...2912 °F
Set point SP251...1600 °C
484...2912 °F
251...1600 °C484...2912 °F
Reset point rP250...1599 °C
482...2910 °F
250...1599 °C482...2910 °F
Analogue start point250...1400 °C
482...2552 °F
250...1400 °C482...2552 °F
Analogue end point450...1600 °C
842...2912 °F
450...1600 °C842...2912 °F
In steps of1 °C
1 °F
1 °C1 °F
Resolution of switching output[K] [K]1
Resolution of analogue output[K] [K]0.2; (+ 0.03% of the set measuring span)
Resolution of display[K] [K]1

Accuracy / deviations

Accuracy[K] [K]< ± 0,5 %; (of measured value, min. 4 K (degree of emission = 1, T = 23 °C))
Repeatability[K] [K]1

Response times

Response time[ms] [ms]2; (T > 600 °C)

Software / programming

Adjustment of the switch pointprogramming buttons
Parameter setting optionsanalogue range; normally open / normally closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Function
Device diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue16
Process data binary1
Min. process cycle time[ms] [ms]3.6
Supported DeviceIDsdefault
717
default717

Operating conditions

Ambient temperature[°C] [°C]0...65
Storage temperature[°C] [°C]-20...80
Max. relative air humidity[%] [%]95; (non condensing)
ProtectionIP 65

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-4
Shock resistanceDIN EN 60068-2-27
30 g (11 ms)
DIN EN 60068-2-2730 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]74.3

Mechanical data

Weight[g] [g]465
Housingthreaded type
Dimensions[mm] [mm]M30 x 1.5 / L = 214
Thread designationM30 x 1.5
Materialsthreaded sleeve: stainless steel (303/1.4305); polyester
Lens materialtempered optical glass

Displays / operating elements

DisplayDisplay unit
2 x LED, yellow
switching status
1 x LED, yellow
function display
7-segment LED display, 4-digit
measured values
7-segment LED display, 4-digit
Display unit2 x LED, yellow
switching status1 x LED, yellow
function display7-segment LED display, 4-digit
measured values7-segment LED display, 4-digit
Operating elements3
pushbuttons
3pushbuttons

Accessories

Items suppliedlock nuts: 2

Remarks

RemarksUse a screened cable to protect infrared temperature sensors from interference.
The screen must be connected to the housing of the sensor via the connector.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12

Customer Reviews