Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range5...3000 ml/min
0.005...3 l/min
5...3000 ml/min0.005...3 l/min
Process connectionthreaded connection G 1/4 external thread DN6 flat seal

Application

Special featureGold-plated contacts
Applicationtotaliser function; for industrial applications
Installationconnection to pipe by means of an adapter
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature[°C] [°C]0...60
Pressure rating10 bar
1 MPa
10 bar1 MPa
MAWP for applications according to CRN8.6 bar
0.86 MPa
8.6 bar0.86 MPa

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]200
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range5...3000 ml/min
0.005...3 l/min
5...3000 ml/min0.005...3 l/min
Display range[ml/min] [ml/min]-1999...3600
Resolution[ml/min] [ml/min]1
Set point SP[ml/min] [ml/min]20...3000
Reset point rP[ml/min] [ml/min]5...2984
Analogue start point ASP[ml/min] [ml/min]0...2400
Analogue end point AEP[ml/min] [ml/min]600...3000
Low flow cut-off LFC[ml/min] [ml/min]< 60
Pulse value1...3000 ml
Pulse length[s] [s]0,008...2
Measuring range[°C] [°C]-20...80
Resolution[°C] [°C]0.2
Set point SP[°C] [°C]-19.2...80
Reset point rP[°C] [°C]-19.6...79.6
Analogue start point[°C] [°C]-20...60
Analogue end point[°C] [°C]0...80
In steps of[°C] [°C]0.2

Accuracy / deviations

Accuracy (in the measuring range)± (2 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Accuracy[K] [K]± 2,5 (Q > 0,5 l/min)

Response times

Response time[s] [s]0.15; (dAP = 0, T19)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 40 (Q > 1 l/min)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Function
Device diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault
671
default671

Operating conditions

Ambient temperature[°C] [°C]-10...60
Storage temperature[°C] [°C]-25...80
ProtectionIP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number
007MI
accuracy class
-
maximum allowable error
± 2,5 % FS
Q (min)
0,0003 m³/h
Q (t)
-
Q (max)
0,18 m³/h
model number007MI
accuracy class-
maximum allowable error± 2,5 % FS
Q (min)0,0003 m³/h
Q (t)-
Q (max)0,18 m³/h
Shock resistanceDIN IEC 68-2-27
20 g (11 ms)
DIN IEC 68-2-2720 g (11 ms)
Vibration resistanceDIN IEC 68-2-6
5 g (10...2000 Hz)
DIN IEC 68-2-65 g (10...2000 Hz)
MTTF[years] [years]144
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]536.5
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]Ø 54 / L = 110
Materialsstainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (316L/1.4404); PEEK; FKM
Process connectionthreaded connection G 1/4 external thread DN6 flat seal

Displays / operating elements

DisplayDisplay unit
6 x LED, green (ml/min, l/h, l, m³, °C, 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit6 x LED, green (ml/min, l/h, l, m³, °C, 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range