Description

Precise measurement of flow, consumption and medium temperature
High accuracy, repeatability and measurement dynamics
Precise empty pipe detection
With switching output, analogue output and pulse output
Clearly visible 4-digit LED display
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range80...9600 gph
1.3...160 gpm
80...9600 gph1.3...160 gpm
Process connectionthreaded connection 2" NPT internal thread DN50

Application

Special featureGold-plated contacts
Applicationtotaliser function; empty pipe detection; for industrial applications
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature[°F] [°F]14...194
Pressure rating16 bar
232 psi
1.6 MPa
16 bar232 psi
MAWP for applications according to CRN8.9 bar
0.89 MPa
8.9 bar0.89 MPa

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 150
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Frequency of the output[Hz] [Hz]0.1...10000

Measuring/setting range

Measuring range80...9600 gph
1.3...160 gpm
80...9600 gph1.3...160 gpm
Display range-11520...11520 gph
-190...190 gpm
-11520...11520 gph-190...190 gpm
Resolution5 gph
0.1 gpm
5 gph0.1 gpm
Set point SP130...9600 gph
2.1...160 gpm
130...9600 gph2.1...160 gpm
Reset point rP80...9550 gph
1.3...159.2 gpm
80...9550 gph1.3...159.2 gpm
Analogue start point ASP0...7680 gph
0...128 gpm
0...7680 gph0...128 gpm
Analogue end point AEP1920...9600 gph
32...160 gpm
1920...9600 gph32...160 gpm
Low flow cut-off LFC< 240 gph
< 4 gpm
< 240 gph< 4 gpm
In steps of0.02 gal
Measuring dynamics1:120
Pulse value0.02...160 E06 gal
Pulse length[s] [s]0,008...2
Measuring range[°F] [°F]-4...176
Display range[°F] [°F]-40...212
Resolution[°F] [°F]0.5
Set point SP[°F] [°F]-2...176
Reset point rP[°F] [°F]-3...175
Analogue start point[°F] [°F]-4...140
Analogue end point[°F] [°F]32...176
In steps of[°F] [°F]0.5

Accuracy / deviations

Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Temperature drift± 0,0185 °F / K
Accuracy[K] [K]± 1 (77 °F; Q > 4 gpm)

Response times

Response time[s] [s]0.35; (dAP = 0)
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 3 (Q > 4 gpm)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionProcess data variable
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault
390
default390

Operating conditions

Ambient temperature[°F] [°F]14...140
Storage temperature[°F] [°F]-13...176
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
Shock resistanceDIN EN 60068-2-27
20 g (11 ms)
DIN EN 60068-2-2720 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
5 g (10...2000 Hz)
DIN EN 60068-2-65 g (10...2000 Hz)
MTTF[years] [years]85
UL approvalUL approval no.
I008
File number UL
E174189
UL approval no.I008
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]2643
Housingrectangular
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]180 x 103 x 117
Materialsstainless steel (316L/1.4404); stainless steel (316Ti/1.4571); PEI; FKM; PBT-GF20; TPE-U
Materials (wetted parts)stainless steel (316L/1.4404); stainless steel (316Ti/1.4571); PEEK; FKM
Process connectionthreaded connection 2" NPT internal thread DN50

Displays / operating elements

DisplayDisplay unit
6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status
2 x LED, yellow
measured values
alphanumeric display, 4-digit
programming
alphanumeric display, 4-digit
Display unit6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³)
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Accessories

Items suppliedLabel

Remarks

RemarksMW = measured value
MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated