Fast delivery within 72 Hours

IFM DN4014

DN4014

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

For the regulated power supply for controllers, sensors, actuators, and industrial electronics
Low power loss thanks to high efficiency
High mains buffering time
Particularly space-saving design
High power reserves

Specification

Application

Designhousing for DIN rail mounting

Electrical data

Frequency AC[Hz] [Hz]47...64
Nominal voltage AC[V] [V]< 230
Input voltage range AC[V] [V]100...240; (-15 % / +10 %)
Output voltage DC[V] [V]24...28
Protection classI; (IEC 61140)
Overvoltage protectionyes; (< 32 DC)
Output voltage[V] [V]adjustable; output voltage to SELV, PELV
Max. output current at min. output voltage[A] [A]20
Max. output current at max. output voltage[A] [A]17.1
Max. output current peak at min. output voltage[A] [A]24
Max. output current peak at max. output voltage[A] [A]20.6
Output power (permanent)[W] [W]480
Output power (peak)[W] [W]576
Note on output power (peak)[W] [W]≤ 45 °C permitted continuously; > 45 °C < 1 minute every 10 minutes
Power factor (nominal voltage 120 V AC / 60 Hz)0.99
Power factor (nominal voltage 230 V AC / 50 Hz)0.95
Power reserve[%] [%]20
Number of output circuits1
Max. residual ripple[mV] [mV]50
Switch-on peak current (nominal voltage 120 V AC / 60 Hz)[A] [A]9
Switch-on peak current (nominal voltage 230 V AC / 50 Hz)[A] [A]7
Inrush current limitationyes
Efficiency (nominal voltage 120 V AC / 60 Hz)[%] [%]92.7
Efficiency (nominal voltage 230 V AC / 50 Hz)[%] [%]94
External input protection≥ B-10 A / ≥ C-10 A
Derating[W/K] [W/K]12 (60...70 °C)
Mains buffering time (nominal voltage 120 V AC / 60 Hz)[ms] [ms]26
Mains buffering time (nominal voltage 230 V AC / 50 Hz)[ms] [ms]26
Input current (nominal voltage 120 V AC / 60 Hz)[A] [A]4.36
Input current (nominal voltage 230 V AC / 50 Hz)[A] [A]2.33
Power loss (nominal voltage 120 V AC / 60 Hz)[W] [W]37.8
Power loss (nominal voltage 230 V AC / 50 Hz)[W] [W]30.6
Back feeding protection[V] [V]35

Outputs

Short-circuit proofyes
Overload protectionyes
Overload performanceHiccup Mode; In the event of overload / short circuit, the output alternately supplies continuous power for 2 s and then switches off for 18 s.
Type DC-OK signalrelay output
Reliability of the DC OK signal60 V DC (0.3 A) / 30 V DC (1 A) / 30 V AC (0.5 A)

Operating conditions

Ambient temperature[°C] [°C]-25...70
Note on ambient temperatureobserve the free space for convection (see operating instructions)
Storage temperature[°C] [°C]-40...85
Max. relative air humidity[%] [%]95; (IEC 60068-2-30)
ProtectionIP 20; (EN 60529)
Pollution degree2; (IEC 62103: conductive soiling not permitted)

Tests / approvals

EMCEN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
Class A
EN 61000-3-2Class A
Vibration resistanceIEC 60068-2-6
±1,6 mm 2...17,8 Hz / 2 g 17,8...500 Hz
IEC 60068-2-6±1,6 mm 2...17,8 Hz / 2 g 17,8...500 Hz
Shock resistanceIEC 60068-2-27
30 g 6 ms / 20 g 11 ms
IEC 60068-2-2730 g 6 ms / 20 g 11 ms
MTTF[years] [years]53
Power Factor Correction (PFC)met

Mechanical data

Weight[g] [g]1121.5
Housingrectangular
Type of mountingmounting on DIN rail; (TH35 (EN 60715))
Dimensions[mm] [mm]124 x 65 x 132.5
Materialshousing: steel sheet

Displays / operating elements

DisplayDC ok
1 x LED
DC ok1 x LED

Remarks

RemarksSeries connection of outputs only applies to identical units up to max. 150 V DC overall voltage
Pack quantity1 pcs.

Customer Reviews