Fast delivery within 72 Hours
B&R X90RO440.04-S1
9 to 32 VDC4 safe relay outputsOutput type “Relay”Nominal output current 2x 2 A and 2x 4 ANormally open contactSingle-channel isolated outputsX2X LinkThe relay option board provides 4 additional safe…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
9 to 32 VDC4 safe relay outputsOutput type “Relay”Nominal output current 2x 2 A and 2x 4 ANormally open contactSingle-channel isolated outputsX2X LinkThe relay option board provides 4 additional safe relay outputs. Communication to the mainboard is made possible via X2X Link. The modules can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed within the module. The positively driven feedback contacts are evaluated within the module. The safe digital output modules have a start interlock on error in the event of network errors.
Specification
| I/O module |
4 relays with 1 normally open contact each, 9 to 32 VDC / 2 and 4 A |
|---|---|
| B&R ID code |
0xFB3D |
| Automation Studio |
4.7 or later |
| Automation Runtime |
4.7 or later |
| Mapp Technology Package |
mapp Safety 5.12 and later: |
| Status indicators |
– |
| Module run/error |
Yes, using software |
| Outputs |
Yes, using software |
| Power consumption |
Max. 2 W |
| Max. I/O cycle time |
1 ms |
| Bus |
0.26 W |
| Internal I/O |
1.65 W |
| Additional power dissipation caused by actuators (resistive) [W] |
+3.2 |
| UN ECE-R10 |
Yes |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| MTTFD per channel |
100 years if the relay channel is used individually, |
| Mission time |
Max. 20 years |
| Module |
<2.7*10-7 if the relay channel is used individually, |
| OpenSAFETY wired |
Negligible |
| OpenSAFETY wireless |
<1*10-14 * Number of openSAFETY packets per hour |
| PFD per channel |
<5.6*10-4 if the relay channel is used individually, |
| Proof test interval (PT) |
20 years |
| Category |
KAT 1 if the relay channel is used individually, |
| PL |
PL c if the relay channel is used individually, |
| DC1, 24 VDC |
2 A / 1,800,000 |
| DC13, 24 VDC |
2 A / 121,400 |
| SIL CL |
SIL 1 if the relay channel is used individually, |
| Voltage range |
9 to 32 VDC |
| Quantity |
4 |
| Variant |
Relay / Normally open contact, internal high-side and low-side control |
| Nominal output current |
Relays 1 and 2: 2 A |
| Diagnostic status |
Contact position determined by positively driven contacts |
| Max. switching frequency |
10 Hz |
| 0 → 1 |
<50 ms |
| 1 → 0 |
<20 ms |
| Mechanical |
Min. 1 x 107 ops. |
| Electrical |
Min. 1 x 105 ops. (at 4 A / 32 VDC) |
| Internal |
– |
| External |
Relays 1 and 2: External fuse 2 A |
| Contact resistance (without terminal block) |
80 mΩ |
| Contact service life |
See "Contact service life". |
| Switching voltage range |
5 to 32 VDC |
| Switching current range |
1 mA to 4 A |
| Max. inrush current |
20 A for 25 ms, max. 1x per minute |
| Overvoltage category per EN 60664-1 |
II |
| DC1 |
Relays 1 and 2: 24 VDC / 2 A |
| DC13 |
Relays 1 and 2: 24 VDC / 2 A |
| Electrical isolation |
Channel isolated from channel and bus |
| Any |
Yes |
| Degree of protection per EN 60529 |
IP66, IP69K |
| Horizontal mounting orientation |
-40 to 75°C housing surface |
| Vertical mounting orientation |
-40 to 75°C housing surface |
| Storage |
5 to 100%, condensing |
| Transport |
5 to 100%, condensing |
| Operation |
5 to 100%, condensing |
| Width |
47 mm |
| Length |
95 mm |

Reviews
Clear filtersThere are no reviews yet.