Fast delivery within 72 Hours

B&R X90PO210.08-00

9 to 32 VDC8 PWM outputs4 A per channelCurrent measurementCentral cutoffX2X LinkThe PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication t…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

9 to 32 VDC8 PWM outputs4 A per channelCurrent measurementCentral cutoffX2X LinkThe PWM option board offers 8 additional analog outputs that can also be used as digital inputs/outputs. Communication to the mainboard is implemented using X2X Link. In addition, the PWM option board provides current measurement for each channel.

Specification

I/O module

8 digital inputs/outputs 9 to 32 VDC for 1-wire connections

B&R ID code

0xEBC2

Status indicators

Diagnostic outputs

In the application using current measurement

Power consumption

0.91 W

Digital - Digital

No

UN ECE-R10

Yes

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Quantity

0 to 8, depends on the use of multifunction inputs/outputs

Functions

4 A nominal current / channel
PWM frequency 15 Hz to 1 kHz,
digital input/output, sink/source circuit – configurable per channel, configurable software input filter, configurable switch-on/switch-off ramp, integrated output protection

Input voltage

9 to 32 VDC

Input current at 24 VDC

Typ. 2.7 mA

Input circuit

Sink/Source, configurable

Hardware

100 µs

Software

Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments

Input resistance

Typ. 9 kΩ

Switching threshold

45% supply voltage

Nominal voltage

12/24 VDC

Supply voltage (permissible range)

9 to 32 VDC

Nominal current

4 A

Summation current

16 A

PWM frequency

15 Hz to 1 kHz

Duty cycle

0 to 100% in 0.1% steps, resolution <50 μs

Output circuit

Sink/Source

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads

Variant

Current-sourcing/Current-sinking FET

Diagnostic status

Output monitoring with 1 ms delay

Leakage current when the output is switched off

Max. 50 µA

Residual voltage

<0.1 V at 4 A nominal current

Peak short-circuit current

50 A (max. 0.2 ms)

Current measurement range

±10 A

Conversion time

40 μs

Resolution

12-bit (6 mA)

Data type

INT 0x8001 to 0x7FFF

Current

1 LSB = 305 μA

Accuracy

±0.5% ±50 mA

Temperature drift

±0.02%/°C ±1 mA/°C

Common mode error

±3 mA/V

Any

Yes

Degree of protection per EN 60529

Up to IP69K

Horizontal mounting orientation

-40 to 85°C housing surface

Vertical mounting orientation

-40 to 85°C housing surface

Storage

5 to 100%, condensing

Transport

5 to 100%, condensing

Operation

5 to 100%, condensing

Width

47 mm

Length

95 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X90PO210.08-00”