Fast delivery within 72 Hours

B&R X90DSI00.04-00

18 to 30 VDC4 IO-Link devices4 digital channels, can be used as inputs or outputsSensor/actuator power supplyNetTime timestamps: IO-Link dataX2X LinkThe DS option board is an IO-Link master that allow…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

18 to 30 VDC4 IO-Link devices4 digital channels, can be used as inputs or outputsSensor/actuator power supplyNetTime timestamps: IO-Link dataX2X LinkThe DS option board is an IO-Link master that allows intelligent sensors and actuators to be connected per the IO-Link standard. Communication to the mainboard is made possible via X2X Link.

Specification

I/O module

IO-Link master with 4 IO-Link interfaces

B&R ID code

0xF9F7

Status indicators

Module run/error

Yes, using software status

Internal I/O

0.6 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Voltage

I/O power supply minus voltage drop for short-circuit protection

Voltage drop for short-circuit protection at 0.3 A

Max. 0.3 V

Power consumption

Max. 12 W per IO-Link interface

Short-circuit proof

Yes

Switch-off delay

Configurable using software

Switch-off duration

Configurable using software

COM1

4.8 kbaud

COM2

38.4 kbaud

COM3

230.4 kbaud

Max. connection capacity

22 nF (cable + IO-Link device)

Max. load

96 Ω / 250 mA

Data format

1 start bit, 8 data bits, 1 parity bit (even), 1 stop bit

Bus level

24 VDC (active), 0 VDC (resting voltage)

Variant

Bipolar, positive and negative switching

Peak short-circuit current

<1.3 A

Residual voltage

<0.7 VDC at nominal current 0.25 A

Switching voltage

I/O power supply minus voltage drop for short-circuit protection and semiconductor switch

Voltage drop on semiconductor switch

Max. 0.44 VDC at 0.2 A

Switching frequency

Typ. 25 kHz
300 kHz in IO-Link master mode

0 → 1

<1 µs

1 → 0

<1 µs

Switch-on in the event of overload shutdown or short-circuit shutdown

Configurable with software

Nominal voltage

24 VDC

Nominal output current

0.25 A

Total nominal current

Max. 1 A

Output circuit

Sink or source

Switching frequency (resistive load)

Max. 500 Hz

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads

Input characteristics per EN 61131-2

Type 1

Hardware

220 ns

Software

3 µs (without glitch filter)
4.2 µs (with glitch filter)

Input circuit

Sink

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Typ. 5.8 mA

Input resistance

Typ. 4.14 kΩ

Low

<5 VDC

High

>15 VDC

Electrical isolation

Bus isolated from IO-Link
IO-Link not isolated from IO-Link

Any

Yes

Degree of protection per EN 60529

Up to IP69K

Storage

5 to 100%, condensing

Transport

5 to 100%, condensing

Operation

5 to 100%, condensing

Width

47 mm

Length

95 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.