Fast delivery within 72 Hours

B&R X90CP174.48-00

Agricultural and forestry machinesConstruction equipmentMunicipal utility vehiclesStationary outdoor applicationsPowerful ARM CPU with 650 MHzMultifunction I/O channelsEthernet, POWERLINK, 3x CAN bus,…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Agricultural and forestry machinesConstruction equipmentMunicipal utility vehiclesStationary outdoor applicationsPowerful ARM CPU with 650 MHzMultifunction I/O channelsEthernet, POWERLINK, 3x CAN bus, USBModular expansionThe heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include connections for CAN, USB, Ethernet and the real-time POWERLINK bus system.The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to add I/O channels or interfaces as well as specific functions such as condition monitoring.

Specification

Interfaces

1x Ethernet, 1x USB, 3x CAN bus, 1x POWERLINK

System module

Controller

Insulation voltage for GND and housing

500 Veff

B&R ID code

0xEB3F

Cooling

Fanless

Status indicators

Controller function, overtemperature, Ethernet, POWERLINK

Module run/error

Yes, using LED status indicator and software

CPU function

Yes, using LED status indicator

Ethernet

Yes, using LED status indicator

Controller redundancy

No

Storage health data support

Yes

ACOPOS support

Yes

ReACTION-capable I/O channels

No

Visual Components support

Yes

Power consumption without interface module and USB

CPU at Ue = 9 / 32 V: 3.3 / 3.9 W
I/O at Ue = 9 / 32 V: 0.9 / 3.4 W

UN ECE-R10

Yes

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Input voltage

9 to 32 VDC

Reset switching threshold

6.8 V ±5%

V_CPU

No, required fuse 5 A slow-blow

V_I/O

No, required fuse 10 A slow-blow per connection pin

Overvoltage

48 V ≤5 minutes

Overvoltage protection

Load dump pulse A 202 V Ri = 4 Ω

Reverse polarity protection

-48 V ≤5 minutes

Real-time clock

Resolution 1 s, retention min. 48 hours, typ. 250 hours at 25°C, precision ±30 ppm over the entire temperature range

FPU

Yes

Type

CAN bus

Clock frequency

650 MHz

Data code

32 kB

Program code

32 kB

L2 cache

512 kB

Integrated I/O processor

Processes I/O data points in the background

Option boards

Max. 32 A

Remanent variables

32 kB FRAM, retention >10 years

Shortest task class cycle time

400 µs

RAM

256 MB DDR3 SDRAM

Data retention

10 years

Guaranteed

100 TB

Results for 5 years

54.8 GB/day

Guaranteed erase/write cycles

100,000

Error-correcting code (ECC)

Yes

Variant

Positive/Negative switching FET, channels can be connected in parallel.

Line length

Max. 100 m between 2 stations (segment length)

Transfer rate

Max. 1 Mbit/s

Physical layer

100BASE-TX

Half-duplex

Yes

Full-duplex

No

Autonegotiation

Yes

Auto-MDI/MDIX

Yes

Fieldbus

POWERLINK managing or controlled node

Max. output current

500 mA

Connection designation

CAN3

Max. distance

1000 m

Terminating resistor

External 120 Ω must be provided.

Quantity

0 to 11x 4 A and
0 to 5x 6 A
Depends on the use of multifunction outputs

Functions

Digital output:
4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), sink/source circuit, integrated
output protection per channel, configurable overload monitoring per channel, central cutoff
via relay, parallel connection, current measurement, error state with configurable error filter.
PWM output:
4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 4 kHz,
sink/source circuit, integrated output protection per channel, configurable overload monitoring
per channel, central cutoff via relay, parallel connection, current measurement (asynchronous or
synchronous to PWM period), configurable load current distribution of PWM outputs, dither.
H bridge:
4 A nominal current (PWM 4 A), 6 A nominal current (PWM 6 A), PWM frequency 15 Hz to 8 kHz (at load), integrated output protection per channel, configurable
overload monitoring per channel, central cutoff via relay, parallel connection, current measurement (asynchronous
or synchronous to PWM period), configurable load current distribution of PWM outputs, dither.
Digital input:
Sink/Source circuit configurable per channel, configurable software input filter

Nominal voltage

12 / 24 VDC

Input current at 24 VDC

MF-DI: Typ. 1.2 / 2.5 / 3.6 mA, configurable
MF-AI: Typ. 1.2 / 2.5 / 3.6 mA, configurable
MF-DO: Typ. 2.5 mA
MF-PWM: Typ. 2.5 mA

Input circuit

Sink/Source, configurable

Hardware

MF-DI: 3 μs if switching threshold = 50% supply voltage
MF-AI: 300 μs if switching threshold = 50% supply voltage
MF-DO: 300 μs
MF-PWM: 150 μs

Software

Default 1 ms, configurable between 0 and 25 ms in 0.1 ms increments

Input resistance

MF-AI and MF-DI: Typ. 6.5 / 9 / 18 kΩ, configurable
MF-DO and MF-PWM: 9 kΩ

Input frequency

MF-DI: Max. 50 kHz

Switching threshold

MF-DI: 50% of supply voltage
MF-AI: Switching threshold and hysteresis configurable with software
MF-DO: 42% supply voltage
MF-PWM: 42% supply voltage

Input

0 to 10 V / 0 to 32 V / 0 to 20 mA / 4 to 20 mA / 0 to 50 kΩ / Temperature inputs (Pt1000 characteristic curve)

Digital converter resolution

12-bit

Conversion time

MF-PWM: 40 μs

Data type

INT, UINT (resistance)

Voltage

Sensor power supply 1: 5/10 V
Sensor power supply 2: 5 V

Current

Sensor power supply 1: Max. 400 mA, accuracy: ±3%
Sensor power supply 2: Max. 500 mA, accuracy: ±4%

Resistance

0.0018%/°C

Temperature input

0.027%/°C

Measuring current resistance / Temperature input

<1.6 mA

Open-circuit detection

From the application

Conversion procedure

SAR

Input filter

First-order low-pass filter / cutoff frequency of voltage input 350 Hz, current input 200 Hz

Gain

MF-PWM: <0.2%

Offset

MF-PWM: <0.1%

Nonlinearity

<0.05%, <0.2% (resistance, temperature inputs)

Switching voltage

MF-DO, MF-PWM: V_IO -15%
MF-PVG, MF-AI (ratiometric output) : V_CPU – 15%

Output format

INT
MF-PWM: INT 0x8001 to 0x7FFF / 1 LSB = 305 µA

Nominal output current

MF-DO: 4 A
MF-PWM: 4 A / 6 A

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads

Diagnostic status

Overload

Leakage current when the output is switched off

MF-DO: 10 μA
MF-PWM: 20 μA

RDS(on)

MF-DO: 80 mΩ
MF-PWM: 50 mΩ

Residual voltage

<1 V at 4 A nominal current

Peak short-circuit current

50 A (max. 0.2 ms)

Resistive load

MF-DO: Max. 250 Hz

Inductive load

MF-DO: Load current 4 A: Max. 4 mH (see section "Switching inductive loads")

Braking voltage when switching off inductive loads

MF-DO: Typ. 64 VDC

Switching delay

MF-DO: Max. 150 μs

Nominal

9 to 32 VDC

Sampling time

MF-DO: 160 μs
MF-PWM: 40 μs

Current measurement range

MF-PWM: ±10 A

Max. gain drift

MF-PWM: <0.04%/°C

Max. offset drift

MF-PWM: <0.005%/°C

Supply voltage (permissible range)

9 to 32 VDC

PWM frequency

15 Hz to 4 kHz

Duty cycle

0 to 100%, resolution 0.16 µs

Common mode error

MF-PWM: 0.015%/V

Multifunction digital outputs (MF-DO)

Max. 20 A

Mainboard

Max. 40 A

Complete system

Max. 70 A

Inrush current

Up to 500 A for <300 μs

Electrical isolation

Ethernet (IF2) and POWERLINK (IF3) isolated from each other and from other interfaces

Any

Yes

0 to 2000 m

No limitation

Degree of protection per EN 60529

IP69K

Horizontal mounting orientation

-40 to 85°C housing surface

Vertical mounting orientation

-40 to 85°C housing surface

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 100%, condensing

Width

250 mm

Length

231 mm

Height

44 mm

Weight

Max. 2.3 kg

Content of delivery

2x protective covers for unused female M12 connectors

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X90CP174.48-00”

Your email address will not be published. Required fields are marked *