Fast delivery within 72 Hours

B&R X90CM480.04-00

4-channel vibration measurement and analysis module24-bit resolution at 51.562 kHzIEPE power supplyExtensive characteristic value calculation in the moduleData buffer uploadOption board X90CM480.04-00…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

4-channel vibration measurement and analysis module24-bit resolution at 51.562 kHzIEPE power supplyExtensive characteristic value calculation in the moduleData buffer uploadOption board X90CM480.04-00 provides a compact system for measuring and analyzing vibrations for use in applications such as condition monitoring for machinery and equipment.The measurement unit consists of 4 vibration inputs with 24-bit converter resolution and a sampling frequency of 51.562 kHz. Each of the inputs has a separately switchable constant current source for supplying power to the IEPE sensors.The option board integrates numerous algorithms for signal processing. These include configurable high and low pass filters, envelope generation and Fourier transformation.Various parameters and configurable frequency bands are available to ensure seamless signal evaluation. The module performs calculations internally to minimize the load on the bus and CPU.Whether used for traditional condition monitoring or as a means of process optimization, the maximum evaluable frequency of 10 kHz and maximum frequency resolution of under 63 mHz make the option board suitable for almost any application. If desired, the option board can also be used as a standard input module.The ability to upload all values in the time and frequency domain also allows measurements to be evaluated externally or archived.

Specification

I/O module

X90 mobile 4-channel analog input module for vibration measurement and analysis of condition monitoring tasks

Nominal voltage

9 to 32 VDC

B&R ID code

0xEF81

Power consumption

1.59 W

Channel - Channel

No

Channel - I/O power supply

No

UN ECE-R10

Yes

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Quantity

4

Input type

IEPE sensor: Acceleration

Offset (based on 20 V measurement range)

±0.2%

Gain with sinusoidal signal where f = 100 Hz

±1%

Max. offset drift (based on 20 V measurement range)

±0.005 %/°C

Max. gain drift with sinusoidal signal where f = 100 Hz

±0.020 %/°C

Accuracy of frequency response (1 Hz to 10 kHz)

±5%

Digital converter resolution

24-bit

Short-circuit proof

Yes

Per channel

Yes

Threshold voltage, typical

Starting at 21.3 V (or greater) for more than 1 ms

Common-mode voltage (UCM)

-1 to 17 V

Differential voltage (UD)

UCM ≤ 7 V: ±10 V
UCM > 7 V: ±(17 V – UCM)

Conversion procedure

Sigma-delta

Crosstalk between channels

≤-70 dB

Type

Vibration input

Sampling frequency

51.5625 kHz

Input high pass cutoff frequency

36 mHz

Input low pass cutoff frequency

20 kHz

Downsampling

200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz (configurable)

Frequency resolution of spectra

0.0629 Hz, 0.1574 Hz, 0.3147 Hz, 0.6294 Hz, 1.5736 Hz, 3.1471 Hz

Sensor power supply

IEPE, 5 mA constant current source (4.9 – 5.5 mA), can be switched off for each channel

Any

Yes

Degree of protection per EN 60529

IP69K

Horizontal mounting orientation

-40 to 85°C housing surface

Vertical mounting orientation

-40 to 85°C housing surface

Storage

5 to 100%, condensing

Transport

5 to 100%, condensing

Operation

5 to 100%, condensing

Width

47 mm

Length

95 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.