Fast delivery within 72 Hours

B&R X90AISG0.02-00

9 to 32 VDC2 full-bridge strain gauge inputsData output rate configurable from 2.5 Hz to 7.5 kHzSpecial operating modes (synchronous mode and multisampling)Configurable filter levelThis module is equi…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

9 to 32 VDC2 full-bridge strain gauge inputsData output rate configurable from 2.5 Hz to 7.5 kHzSpecial operating modes (synchronous mode and multisampling)Configurable filter levelThis module is equipped with 2 inputs for evaluating full-bridge strain gauges and works with 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. Communication to the mainboard is made possible via X2X Link.

Specification

I/O module2 full-bridge strain gauge inputs
B&R ID code0xF79D
Status indicators
UN ECE-R10Yes
CEYes
UKCAYes
CRA (Cyber Resilience Act)In preparation
Quantity2
FunctionsAnalog input, 24-bit digital converter resolution
Strain gauge factor2 to 256 mV/V, configurable using software
Connection4- or 6-wire connections
Input typeDifferential, used to evaluate a full-bridge strain gauge
Digital converter resolution24-bit
Conversion timeDepends on the configured data output rate
Data output rate2.5 to 7,500 samples per second, configurable using software (fDATA)
Cutoff frequency5 kHz
Order3
Slope60 dB
ADC filter characteristicsSigma-delta, see section “Filter characteristics of the sigma-delta A/D converter”
Operating range / Measurement sensor85 to 5,000 Ω
Influence of cable lengthSee section “Calculation example”, sensor cable length: Max. 30 m
Input protectionRC protection
Common-mode range0 to 3 VDC Permissible input voltage range (with regard to the electric potential strain gauge GND) on inputs “Input +” and “Input -“
Conversion procedureSigma-delta
Broken bridge supply lineValue approaching 0
Broken sensor lineValue approaching ±end value (status bit “Line monitoring” is set in register “Module status”)
Valid range of values0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607)
Voltage5.5 VDC / Max. 65 mA
Short-circuit and overload-proofYes
Voltage drop for short-circuit protectionMax. 0.2 VDC at 65 mA and 25°C
2 mV/V1.31 nV
4 mV/V2.62 nV
8 mV/V5.25 nV
16 mV/V10.49 nV
32 mV/V20.98 nV
64 mV/V41.96 nV
128 mV/V83.92 nV
256 mV/V167.85 nV
Max. gain drift12 ppm/°C
Max. offset drift2 ppm/°C
Nonlinearity<10 ppm
AnyYes
Chemical resistanceNot guaranteed
Degree of protection per EN 60529Up to IP66
Horizontal mounting orientation-40 to 85°C housing surface
Vertical mounting orientation-40 to 85°C housing surface
Storage5 to 100%, condensing
Transport5 to 100%, condensing
OperationFor shock test 50 g, 11 ms analog values out of tolerance
Width47 mm
Length95 mm
M120.6 Nm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X90AISG0.02-00”

Your email address will not be published. Required fields are marked *