B&R X67BC4321.L08-10

Fieldbus: CANopen16 digital channels, configurable as inputs or outputsAuto-configuration of I/O modulesEasy I/O configuration using Automation Studio V4.3 or laterConstant response times even with la…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Fieldbus: CANopen16 digital channels, configurable as inputs or outputsAuto-configuration of I/O modulesEasy I/O configuration using Automation Studio V4.3 or laterConstant response times even with large amounts of data (max. 32 Rx and 32 Tx PDOs)Configurable I/O cycle (0.5 to 4 ms)Possible to configure the transfer rate or have it detected automaticallyHeartbeat consumer and producer, emergency producer2x SDO server, NMT slaveSimple bootup (autostart)

Controller Area Network (CAN) is widespread in automation technology. CAN topology is based on a line structure and uses twisted wire pairs for data transfer. CANopen is a higher-layer protocol based on CAN. The standardized protocol offers very flexible configuration options.This bus controller makes it possible to connect up to 253 X2X Link I/O modules to CANopen. A transition between IP20 and IP67 protection is possible by directly connecting X20, X67 or XV modules to one another at distances of up to 100 m each across control cabinet boundaries as required. All CANopen operating modes such as synchronous, event and polling are supported as well as PDO linking, life/node guarding, heartbeat, emergency objects and much more. With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description). Automation Studio V4.3 or later can be used to easily create configuration files (e.g. DCF files). All other function models are also supported by transferring configuration data to the bus controller (e.g. via the master environment with an SDO download). Automation Studio can be downloaded at no cost from the B&R website (www.br-automation.com). The evaluation license is permitted to be used to create complete configurations for fieldbus bus controllers at no cost.

Specification

Bus controller

0xB129

Inputs/Outputs

16x M8, 3-pin

Insulation voltage between channel and bus

500 Veff

Nominal voltage

24 VDC

Internal I/O module

0xB529

Sensor/Actuator power supply

Max. 12 W

Status indicators

I/O function per channel, supply voltage, bus function

Outputs

Yes, using LED status indicator and software

I/O power supply

M8, 4-pin

Fieldbus

No limitation

Power output

15 W X2X Link power supply for I/O modules

Internal I/O

3.71 W

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

ATEX

Zone 2, II 3G Ex nA IIA T5 Gc
IP67, Ta = 0 – Max. 60°C
TÜV 05 ATEX 7201X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

KC

Yes

Variant

Current-sourcing FET

Max. distance

1000 m

Transfer rate

Max. 1 Mbit/s

Default transfer rate

Automatic transfer rate detection

Synchronization between bus systems possible

No

Terminating resistor

Can be optionally screwed onto the integrated Y-connector

Voltage range

18 to 30 VDC

Integrated protective function

Reverse polarity protection

Voltage

I/O power supply minus voltage drop for short-circuit protection

Voltage drop for short-circuit protection at 0.5 A

Max. 2 VDC

Summation current

Max. 0.5 A

Short-circuit proof

Yes

Input characteristics per EN 61131-2

Type 1

Input voltage

18 to 30 VDC

Input current at 24 VDC

Typ. 4 mA

Input circuit

Sink

Hardware

≤10 μs (channels 1 to 4) / ≤70 µs (channels 5 to 16)

Software

Default 0 ms, configurable between 0 and 25 ms in 0.2 ms intervals

Input resistance

Typ. 6 kΩ

Additional functions

50 kHz event counting, gate measurement

Low

<5 VDC

High

>15 VDC

Quantity

1

Signal form

Square wave pulse

Evaluation

Positive edge – Negative edge

Input frequency

Max. 50 kHz

Counter 1

Input 1

Counter 2

Input 3

Counter frequency

Max. 50 kHz

Counter size

16-bit

Internal

48 MHz, 3 MHz, 187.5 kHz

Length of pause between pulses

≥100 µs

Pulse length

≥20 µs

Supported inputs

Input 2 or input 4

Switching voltage

I/O power supply minus residual voltage

Nominal output current

0.5 A

Total nominal current

8 A

Output circuit

Source

Output protection

Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads, reverse polarity protection of the output power supply

Diagnostic status

Output monitoring with 10 ms delay

Leakage current when the output is switched off

5 µA

Switching on after overload shutdown

Approx. 10 ms (depends on the module temperature)

Residual voltage

<0.3 V at 0.5 A nominal current

Peak short-circuit current

<12 A

0 → 1

<400 µs

1 → 0

<400 µs

Resistive load

Max. 100 Hz

Inductive load

See section "Switching inductive loads".

Braking voltage when switching off inductive loads

50 VDC

Electrical isolation

Bus isolated from CANopen and channel

Channel isolated from CANopen

Channel not isolated from channel

Any

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP67

Operation

-25 to 60°C

Derating

Storage

-40 to 85°C

Transport

-40 to 85°C

Width

53 mm

Height

155 mm

Depth

42 mm

Weight

300 g

M8

Max. 0.4 Nm

M12

Max. 0.6 Nm