B&R X20SRT402

reACTION Technology module4 high-speed safe digital inputs, sink circuit4 pulse outputsSoftware input filter configurable for each channel2 high-speed safe digital outputs, output type B with 0.2 A, s…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

reACTION Technology module4 high-speed safe digital inputs, sink circuit4 pulse outputsSoftware input filter configurable for each channel2 high-speed safe digital outputs, output type B with 0.2 A, source circuitSafe reACTION task cycle times starting at 150 µsIntegrated output protection

This reACTION Technology module is equipped with 4 high-speed safe digital inputs and 2 high-speed safe digital outputs. It is designed for a nominal voltage of 24 VDC.The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3.Ultrafast reACTION Technology makes it possible to control internal I/O channels with cycle times down to 150 µs. All commands that can be used for reACTION programs are available as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio.The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of switching cycles. The “high-side high-side” variant (output type B) is required for actuators with reference potential (e.g. enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. The safe digital output modules are equipped with an error interlock in the event of network errors.This module is designed for X20 12-pin terminal blocks.

Specification

I/O module

4 safe type A digital inputs, 4 pulse outputs, 24 VDC, 2 safe type B2 digital outputs, 24 VDC, 0.2 A, OSSD <10 µs, reACTION Technology

B&R ID code

0xE7EC

Automation Studio

4.2.5 or later

Automation Runtime

4.2 or later

SafeDESIGNER

4.2.2 or later

Safety Release

1.10 or later

Mapp Technology Package

mapp Safety 5.7.0 or later

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software

Inputs

Yes, using LED status indicator and software

ReACTION-capable I/O channels

Yes

Scope

Module

Function

Programmable

Standalone mode

Yes

Max. I/O cycle time

800 µs

Bus

0.4 W

Internal I/O

2.5 W

Safe digital HS-HS outputs

0.4

Pulse outputs

0.8

Channel - Bus

Yes

Channel - Channel

No

Type of signal lines

Shielded lines must be used for all signal lines.

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Functional safety

EN 50156-1:2004

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

DNV

In preparation

Mission time

Max. 20 years

OpenSAFETY wired

Negligible

OpenSAFETY wireless

<1*10-14 * Number of openSAFETY packets per hour

Proof test interval (PT)

20 years

Category

Cat. 3 if parameter "Disable OSSD = Yes – Warning",
Cat. 4 if parameter "Disable OSSD = No"

PL

PL d if parameter "Disable OSSD = Yes – Warning",
PL e if parameter "Disable OSSD = No"

DC

>60% if parameter "Disable OSSD = Yes – Warning",
>94% if parameter "Disable OSSD = No"

MTTFD per channel

100 years if parameter "Disable OSSD = Yes – Warning",
2500 years if parameter "Disable OSSD = No"

SIL CL

SIL 2 if parameter "Disable OSSD = Yes – Warning",
SIL 3 if parameter "Disable OSSD = No"

SFF

>60% if parameter "Disable OSSD = Yes – Warning",
>90% if parameter "Disable OSSD = No"

PFH / PFHd per channel

<5*10-8 if parameter "Disable OSSD = Yes – Warning",
<1*10-10 if parameter "Disable OSSD = No"

PFD per channel

<1*10-3 if parameter "Disable OSSD = Yes – Warning",
<2*10-5 if parameter "Disable OSSD = No"

Nominal voltage

24 VDC

Voltage range

24 VDC -15% / +20%

Integrated protective function

Reverse polarity protection

Quantity

4

Variant

Push-Pull

Input characteristics per EN 61131-2

Type 1

Hardware

≤130 µs

Software

Configurable between 0 and 500 ms

Input circuit

Sink

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Min. 2 mA to max. 3.28 mA

Input resistance

Min. 7.33 kΩ

Error detection time

1 s

Insulation voltage between channel and bus

500 Veff

Low

<5 VDC

High

>15 VDC

Line length between signal source (pulse output or external signal) and input

Max. 60 m with unshielded line
Max. 400 m with shielded line

Nominal output current

50 mA

Total nominal current

200 mA

Output protection

Shutdown of individual channels in the event of overload or short circuit

Braking voltage when switching off inductive loads

Max. 45 VDC

Peak short-circuit current

0.5 A for 120 µs

Leakage current when the output is switched off

0.1 mA

RDS(on)

80 Ω

Switching voltage

I/O power supply minus voltage drop due to RDS(on)

Max. switching frequency

See section "Inrush current behavior for output channels".

Test pulse length

Max. 10 µs

Max. capacitive load

100 nF

IOUT

<100 µA

IGND

<200 mA

Short-circuit current

15 mAeff

Horizontal

Yes

Vertical

Yes

Installation elevation above sea level

0 to 2000 m, no limitation

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

0 to 60°C

Vertical mounting orientation

0 to 50°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 2x safety-keyed terminal block separately.
Order 1x safety-keyed bus module separately.

Pitch

25+0.2 mm