Fast delivery within 72 Hours
B&R X20SM1426
1Â stepper motor, 24Â VDC, 1 A (1.2 A peak)Resolution of current values at 1%Maximum, rated and holding current configured independent of each other38.5 kHz PWM frequencyIntegrated motor detection256 mi…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
1Â stepper motor, 24Â VDC, 1 A (1.2 A peak)Resolution of current values at 1%Maximum, rated and holding current configured independent of each other38.5 kHz PWM frequencyIntegrated motor detection256 micro-stepsStall detectionComplete integration in Automation Studio and CNC applications4 inputs, 24 VDC, can be configured as ABRRamp function model based on the CANopen communication profile DS402NetTime timestamp: Position change, trigger time
The stepper motor module is used to control stepper motors with a rated voltage of 24 VDC at a motor current up to 1 A (1.2 A peak). Additionally, this module has four digital inputs that can be used as limit switches or as encoder inputs.Due to the individual adjustment of the coil currents, the motor is only operated with the current it actually needs. This simplifies the selection of the available motors and prevents unnecessary heating. Because this affects energy consumption and thermal load, the effects are positive on the service life of the complete system. Complete flexibility is achieved through the use of independently adjustable holding, maximum and nominal current values. The current for microsteps is automatically adjusted to the configured current values.The automatic motor identification system is an enormous help during standstills. The stepper motor modules can identify the connected motors using their coil characteristics and generate feedback in the form of an analog value. This makes it possible to detect not only wiring errors, but also incorrect motor types being used mistakenly. “Stall detection” is integrated to analyze the motor load. Detection of the stall is defined via a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.
Specification
| I/O module |
1 full bridge for controlling stepper motors |
|---|---|
| B&R ID code |
0x2681 |
| Status indicators |
I/O function per channel, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Output |
Yes, using LED status indicator and software |
| I/O power supply |
Yes, using software |
| Bus |
0.01 W |
| Internal I/O |
1.8 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 GcIP20, Ta (see X20 user's manual)FTZÚ 09 ATEX 0083X |
| UL |
cURus E225616Power conversion equipment |
| HazLoc |
cCSAus 244665Process control equipmentfor hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC |
Yes |
| Quantity |
1 |
| Type |
2-phase bipolar stepper motor (full bridge) |
| Nominal voltage |
24 VDC -15% / +20% |
| Nominal current |
1 A |
| Maximum current |
1.2 A for 2 s (after a recovery time of at least 10 s at maximum 1 A) |
| Controller frequency |
38.4 kHz |
| DC bus capacitance |
57 µF |
| Step resolution |
Max. 256 microsteps per step |
| Input circuit |
Sink |
| Hardware |
<5 µs |
| Software |
– |
| Connection type |
1-wire connections |
| Input resistance |
Typ. 18.2 kΩ |
| Additional functions |
1x ABR incremental encoder |
| Low |
<5 VDC |
| High |
>15 VDC |
| Encoder inputs |
24 V, asymmetrical |
| Counter size |
16-bit |
| Input frequency |
Max. 50 kHz |
| Evaluation |
4x |
| Electrical isolation |
Channel isolated from busChannel not isolated from I/O power supply |
| Horizontal |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C (Rev. > E6), 0 to 55°C (Rev. ≤ E6) |
| Vertical mounting orientation |
Not permitted |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately.Order 1x bus module X20BM11 separately. |
| Pitch |
12.5+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.