Fast delivery within 72 Hours
B&R X20SLX410
openSAFETY manager for up to 10 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management4 s…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
openSAFETY manager for up to 10 SafeNODEsFlexibly programmable using Automation Studio / SafeDESIGNERInnovative management of safe machine options (SafeOPTION)Parameter and configuration management4 safe digital inputs4 pulse outputsSink circuitSoftware input filter configurable for each channel
The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU.In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).
Specification
| I/O module |
4 safe type A digital inputs, 4 pulse outputs, 24 VDC, SafeLOGIC-X technology |
|---|---|
| B&R ID code |
0xC5B2 |
| Status indicators |
I/O function per channel, operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Inputs |
Yes, using LED status indicator and software |
| Max. I/O cycle time |
1600 µs |
| Bus |
0.32 W |
| Internal I/O |
1.25 W |
| Additional power dissipation caused by actuators (resistive) [W] |
0.6 |
| Channel - Bus |
Yes |
| Channel - Channel |
No |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| Functional safety |
EN 50156-1:2004 |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: A (0 to 45°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC21B |
| KC |
Yes |
| Note |
Order 1x safety-keyed terminal block separately. |
| FB instances |
256 |
| Marker memory |
5120 bytes (0x1400) |
| Stack memory |
2048 bytes |
| Memory for safe input data |
128 bytes, 68 bytes of which are usable for modules |
| Memory for safe output data |
64 bytes |
| Memory for standard input data |
64 bytes |
| Memory for standard output data |
64 bytes |
| Marker count |
256 |
| Max. number of function block types |
64 |
| Max. number of force variables |
8 |
| Max. number of variable with variable status |
128 |
| Nominal voltage |
24 VDC |
| Voltage range |
24 VDC -15% / +20% |
| Integrated protective function |
Reverse polarity protection |
| Quantity |
4 |
| Variant |
Push-Pull |
| Input characteristics per EN 61131-2 |
Type 1 |
| Hardware |
≤150 µs |
| Software |
Configurable between 0 and 500 ms |
| Input circuit |
Sink |
| Input voltage |
24 VDC -15% / +20% |
| Input current at 24 VDC |
Min. 2 mA to max. 3.28 mA |
| Input resistance |
Min. 7.33 kΩ |
| Error detection time |
200 ms |
| Insulation voltage between channel and bus |
500 Veff |
| Low |
<5 VDC |
| High |
>15 VDC |
| Line length between signal source (pulse output or external signal) and input |
Max. 60 m with unshielded line |
| Nominal output current |
50 mA |
| Output protection |
Shutdown of individual channels in the event of overload or short circuit |
| Peak short-circuit current |
25 A for 15 µs |
| Short-circuit current |
100 mAeff |
| Leakage current when the output is switched off |
0.1 mA |
| RDS(on) |
60 Ω |
| Switching voltage |
I/O power supply minus voltage drop due to RDS(on) |
| Total nominal current |
200 mA |
| Horizontal |
Yes |
| Vertical |
Yes |
| Installation elevation above sea level |
0 to 2000 m, no limitation |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
0 to 60°C |
| Vertical mounting orientation |
0 to 50°C |
| Derating |
See section "Derating". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Pitch |
25+0.2 mm |

Reviews
Clear filtersThere are no reviews yet.