Fast delivery within 72 Hours

B&R X20SL8011

SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related configuration of the application. When replacements are needed, the parameter management system makes sure that newly installed modules are assigned correct parameters that apply to the application. Lastly, SafeLOGIC handles the actual safety-related execution of the application program.

Specification

Interfaces

POWERLINK

System module

CPU

Automation Studio

3.0.80 or later

Automation Runtime

3.00 or later

SafeDESIGNER

2.71 and later, up to 3.0

Safety Release

1.3 and later, up to 1.6

Cooling

Fanless

Status indicators

CPU function, POWERLINK, SafeKEY

CPU function

Yes, using LED status indicator

SafeKEY

Yes, using LED status indicator

Power consumption

5.1 W

CE

Yes

UKCA

Yes

Functional safety

EN 50156-1:2004

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: A (0 to 45°C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC21B
Temperature: 5 – 45°C
Vibration: 0.7 g
EMC: Bridge and open deck

KC

Yes

Category

Cat. 4

PL

PL e

DC

>94%

MTTFD per channel

2500 years

Mission time

Max. 20 years

SIL CL

SIL 3

SFF

>90%

Module

<1*10-10

OpenSAFETY wired

Negligible

OpenSAFETY wireless

<1*10-14 * Number of openSAFETY packets per hour

PFD per channel

<2*10-5

Proof test interval (PT)

20 years

Number of supported safety nodes

Max. 100

Communication with each other

Free communication with max. 10 other SafeLOGIC controllers possible

Support for machine options

Yes

SafeMOTION support

Yes

Shortest task class cycle time

1 ms

Type

POWERLINK

Variant

Internal 2-port hub, 2x shielded RJ45 port

Line length

Max. 100 m between 2 stations (segment length)

Transfer rate

100 Mbit/s

Cycle time

Max. 20 ms

Nominal voltage

24 VDC -15% / +20%

Fuse

Integrated, cannot be replaced

Reverse polarity protection

Yes

Horizontal

Yes

Vertical

Yes

Installation elevation above sea level

0 to 2000 m, no limitation

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

0 to 55°C

Vertical mounting orientation

0 to 45°C

Derating

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order application memory (SafeKEY) separately.
X20 end cover plate (right) is included in delivery.
12-pin X20 terminal block, safety-keyed, is included in delivery.
SafeKEY cover is included in delivery.

Width

87.5+0.2 mm

Height

99 mm

Depth

75 mm

Weight

290 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20SL8011”

Your email address will not be published. Required fields are marked *