Fast delivery within 72 Hours
 
					B&R X20SL8001
SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related…
Shipping & Delivery
- 
Courier delivery 
Our courier will deliver to the specified address
2-3 Days
From $20
- 
DHL Courier delivery 
DHL courier will deliver to the specified address
2-3 Days
From $40
- 
Warranty 1 year 
- 
Free 30-Day returns 
Description
SafeLOGIC controllers handle all central tasks within a safety-related application. Three different functional areas exist here. The configuration management system monitors the entire safety-related configuration of the application. When replacements are needed, the parameter management system makes sure that newly installed modules are assigned correct parameters that apply to the application. Lastly, SafeLOGIC handles the actual safety-related execution of the application program.
Specification
| Interfaces | POWERLINK | 
|---|---|
| System module | CPU | 
| Automation Studio | 3.0.71 or later | 
| Automation Runtime | 2.95 or later | 
| SafeDESIGNER | 2.58 and later, up to 3.0 | 
| Safety Release | 1.1 and later, up to 1.6 | 
| Cooling | Fanless | 
| Status indicators | CPU function, POWERLINK, SafeKEY | 
| CPU function | Yes, using LED status indicator | 
| POWERLINK | Yes, using LED status indicator | 
| SafeKEY | Yes, using LED status indicator | 
| Power consumption | 5.1 W | 
| CE | Yes | 
| UKCA | Yes | 
| Functional safety | EN 50156-1:2004 | 
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc | 
| UL | cULus E115267 | 
| HazLoc | cCSAus 244665 | 
| DNV | Temperature: A (0 to 45°C) | 
| CCS | Yes | 
| LR | ENV1 | 
| KR | Yes | 
| ABS | Yes | 
| BV | EC21B | 
| KC | Yes | 
| Category | Cat. 4 | 
| PL | PL e | 
| DC | >94% | 
| MTTFD per channel | 2500 years | 
| Mission time | Max. 20 years | 
| SIL CL | SIL 3 | 
| SFF | >90% | 
| Module | <1*10-10 | 
| OpenSAFETY wired | Negligible | 
| OpenSAFETY wireless | <1*10-14 * Number of openSAFETY packets per hour | 
| PFD per channel | <2*10-5 | 
| Proof test interval (PT) | 20 years | 
| Number of supported safety nodes | Max. 100 | 
| Communication with each other | Free communication with max. 10 other SafeLOGIC controllers possible | 
| Support for machine options | Yes | 
| SafeMOTION support | No | 
| Shortest task class cycle time | 1 ms | 
| Type | POWERLINK | 
| Variant | Internal 2-port hub, 2x RJ45 shielded | 
| Line length | Max. 100 m between 2 stations (segment length) | 
| Transfer rate | 100 Mbit/s | 
| Cycle time | Max. 20 ms | 
| Nominal voltage | 24 VDC -15% / +20% | 
| Fuse | Integrated, cannot be replaced | 
| Reverse polarity protection | Yes | 
| Horizontal | Yes | 
| Vertical | Yes | 
| Installation elevation above sea level | 0 to 2000 m, no limitation | 
| Degree of protection per EN 60529 | IP20 | 
| Horizontal mounting orientation | 0 to 55°C | 
| Vertical mounting orientation | 0 to 45°C | 
| Derating | – | 
| Storage | 5 to 95%, non-condensing | 
| Transport | 5 to 95%, non-condensing | 
| Operation | 5 to 95%, non-condensing | 
| Note | Order application memory (SafeKEY) separately. | 
| Width | 87.5+0.2 mm | 
| Height | 99 mm | 
| Depth | 75 mm | 
| Weight | 290 g | 
 
	 
	 
				 
				
 
		 
		 
		 
		 
		 
		 
		