Fast delivery within 72 Hours

B&R X20SC0842

8 safe digital inputs, sink circuit4 pulse outputsSoftware input filter configurable for each channel4 safe digital outputs, output type A with 3 A, source circuit2 safe digital outputs, output type B…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

8 safe digital inputs, sink circuit4 pulse outputsSoftware input filter configurable for each channel4 safe digital outputs, output type A with 3 A, source circuit2 safe digital outputs, output type B with 50 mA, source circuitIntegrated output protection

The module is equipped with 8 safe digital inputs and 6 safe digital outputs. It is designed for a nominal voltage of 24 VDC.The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3.The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The “high-side low-side” variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. The “high-side high-side” variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur.This module is designed for X20 12-pin terminal blocks.

Specification

I/O module

8 safe type A digital inputs, 4 pulse outputs, 24 VDC, 4 safe type A digital outputs, 24 VDC, 3 A, OSSD <500 µs, 2 safe type B2 digital outputs, 24 VDC, 50 mA, OSSD <500 µs

B&R ID code

0xE7F9

Status indicators

I/O function per channel, operating state, module status

Module run/error

Yes, using LED status indicator and software

Outputs

Yes, using LED status indicator and software

Inputs

Yes, using LED status indicator and software

Scope

Module

Function

Module functionality

Standalone mode

No

Max. I/O cycle time

1 ms

Bus

0.4 W

Internal I/O

2.5 W

Safe digital HS-LS outputs

0.84

Safe digital HS-HS outputs

0.175

Pulse outputs

0.8

Channel - Bus

Yes

Channel - Channel

No

CE

Yes

UKCA

Yes

CRA (Cyber Resilience Act)

In preparation

Functional safety

EN 50156-1:2004

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

Note

Order 2x safety-keyed terminal block separately.
Order 1x safety-keyed bus module separately.

Nominal voltage

24 VDC

Voltage range

24 VDC -15% / +20%

Integrated protective function

Reverse polarity protection

Quantity

4

Variant

Push-Pull

Input characteristics per EN 61131-2

Type 1

Hardware

≤150 µs

Software

Configurable between 0 and 500 ms

Input circuit

Sink

Input voltage

24 VDC -15% / +20%

Input current at 24 VDC

Min. 2 mA to max. 3.28 mA

Input resistance

Min. 7.33 kΩ

Error detection time

1 s

Insulation voltage between channel and bus

500 Veff

Low

<5 VDC

High

>15 VDC

Line length between signal source (pulse output or external signal) and input

Max. 60 m with unshielded line
Max. 400 m with shielded line

Nominal output current

50 mA

Total nominal current

200 mA

Output protection

Shutdown of individual channels in the event of overload or short circuit

Braking voltage when switching off inductive loads

Max. 45 VDC

Error detection

1 s

Peak short-circuit current

0.5 A for 120 µs

Leakage current when the output is switched off

0.1 mA

RDS(on)

80 Ω

Switching voltage

I/O power supply minus voltage drop due to RDS(on)

Max. switching frequency

See section "Inrush current behavior for output channels".

Test pulse length

Max. 500 µs

Max. capacitive load

100 nF

IOUT

<100 µA

IGND

<50 mA

Short-circuit current

15 mAeff

Horizontal

Yes

Vertical

Yes

Installation elevation above sea level

0 to 2000 m, no limitation

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

0 to 60°C

Vertical mounting orientation

0 to 50°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Pitch

25+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20SC0842”

Your email address will not be published. Required fields are marked *