Fast delivery within 72 Hours

B&R X20PS9500

Supply for Compact or Fieldbus CPU, X2X Link network and internal I/O power supplyElectrical isolation of supply and CPU / X2X Link power supplyRedundancy of CPU / X2X Link supply possible by operatin…

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

From $20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From $40

  • Warranty 1 year
  • Free 30-Day returns

Description

Supply for Compact or Fieldbus CPU, X2X Link network and internal I/O power supplyElectrical isolation of supply and CPU / X2X Link power supplyRedundancy of CPU / X2X Link supply possible by operating multiple supply modules simultaneouslyRS232 configurable as an online interfaceCAN bus

The power supply module is used together with an X20 Compact or Fieldbus CPU. It is equipped with a supply for the Compact or Fieldbus CPU, X2X Link network and internal I/O power supply.

Specification

Power supply module

24 VDC power supply module for Compact or Fieldbus CPU, X2X Link power supply and I/O

Interfaces

1x RS232, 1x CAN bus

B&R ID code

0x2018

Status indicators

Overload, operating state, module status, RS232, CAN bus

Module run/error

Yes, using LED status indicator and software

CAN bus data transfer

Yes, using LED status indicator

RS232 data transfer

Yes, using LED status indicator

Overload

Yes, using LED status indicator and software

Internal I/O

0.6 W

Additional power dissipation caused by actuators (resistive) [W]

CE

Yes

UKCA

Yes

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: B (0 to 55°C)
Humidity: B (up to 100%)
Vibration: B (4 g)
EMC: B (bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC33B
Temperature: 5 – 55°C
Vibration: 4 g
EMC: Bridge and open deck

KC

Yes

Input voltage

24 VDC -15% / +20%

Input current

Max. 0.7 A

Fuse

Required line fuse: Max. 10 A, slow-blow

Reverse polarity protection

No

Nominal output power

7 W

Parallel connection

Yes

Redundant operation

Yes

Overload characteristics

Short-circuit proof, temporary overload

Nominal output voltage

24 VDC

Behavior on short circuit

Required line fuse

Permissible contact load

10 A

Signal

CAN bus

Variant

Connection via 12-pin terminal block X20TB12

Transfer rate

Max. 1 Mbit/s

Electrical isolation

CPU/X2X Link supply isolated from CPU/X2X Link power supply

I/O supply not isolated from I/O power supply

Horizontal

Yes

Vertical

Yes

0 to 2000 m

No limitation

>2000 m

Reduction of ambient temperature by 0.5°C per 100 m

Degree of protection per EN 60529

IP20

Horizontal mounting orientation

-25 to 60°C

Vertical mounting orientation

-25 to 50°C

Derating

See section "Derating".

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Operation

5 to 95%, non-condensing

Note

Order 1x terminal block X20TB12 separately.
Order 1x Compact CPU base X20BB22 or X20BB27 separately
Order 1x Fieldbus CPU base X20BB3x/4x separately

Pitch

12.5+0.2 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “B&R X20PS9500”