Fast delivery within 72 Hours
B&R X20PS9402
Supply for the bus controller, X2X Link and internal I/O supplyLow-cost supply module for small X20 systemFeed and bus controller / X2X Link supply not electrically isolatedExpansion or redundancy of…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Supply for the bus controller, X2X Link and internal I/O supplyLow-cost supply module for small X20 systemFeed and bus controller / X2X Link supply not electrically isolatedExpansion or redundancy of bus controller / X2X Link supply not possible by operating multiple supply modules simultaneously
The supply module is used together with an X20 bus controller. It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply. The module is designed to supply power for smaller X20 systems. Potential groups are able to be formed. An expansion or redundancy of the X2X Link with the X20PS3300 or X20PS3310 supply module is not possible. Expansion of the X20 system with a bus transmitter is not permitted either.
Specification
| Power supply module |
24 VDC supply module for bus controller, X2X Link power supply and I/O |
|---|---|
| B&R ID code |
0xA389 |
| Status indicators |
Operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Overload |
Yes, using LED status indicator and software |
| Power consumption for X2X Link power supply |
1.64 W |
| Internal I/O |
0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| KC |
Yes |
| Input voltage |
24 VDC -15% / +20% |
| Input current |
Max. 0.7 A |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
No |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Parallel connection |
No |
| Redundant operation |
No |
| Overload characteristics |
Short-circuit proof, temporary overload |
| Nominal output voltage |
24 VDC |
| Behavior on short circuit |
Required line fuse |
| Permissible contact load |
10 A |
| Electrical isolation |
BC/X2X Link supply not isolated from BC/X2X Link power supply, and I/O supply not isolated from I/O power supply |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Derating |
See section "Derating". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
12.5+0.2 mm |

Reviews