Fast delivery within 72 Hours
B&R X20PS9400
Supply for the bus controller, X2X Link and internal I/O supplyFeed and bus controller / X2X Link supply electrically isolatedRedundancy of bus controller / X2X Link supply possible by operating multi…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Supply for the bus controller, X2X Link and internal I/O supplyFeed and bus controller / X2X Link supply electrically isolatedRedundancy of bus controller / X2X Link supply possible by operating multiple supply modules simultaneouslyService interface (RS232)
The supply module is used together with an X20 bus controller. It is equipped with a feed for the bus controller, the X2X Link and the internal I/O supply.
Specification
| Power supply module |
24 VDC supply module for bus controller, X2X Link power supply and I/O |
|---|---|
| Interfaces |
1x RS232 service interface |
| B&R ID code |
0x1F8C |
| Status indicators |
Overload, operating status, module status, RS232 |
| Module run/error |
Yes, using LED status indicator and software |
| RS232 data transfer |
Yes, using LED status indicator |
| Overload |
Yes, using LED status indicator and software |
| Power consumption for X2X Link power supply |
1.42 W |
| Internal I/O |
0.6 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| KC |
Yes |
| Input voltage |
24 VDC -15% / +20% |
| Input current |
Max. 0.7 A |
| Fuse |
Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection |
No |
| Nominal output power |
7 W |
| Parallel connection |
Yes |
| Redundant operation |
Yes |
| Overload characteristics |
Short-circuit proof, temporary overload |
| Nominal output voltage |
24 VDC |
| Behavior on short circuit |
Required line fuse |
| Permissible contact load |
10 A |
| Signal |
RS232 |
| Variant |
Connection made using 12-pin terminal block X20TB12 |
| Max. transfer rate |
115.2 kbit/s |
| Electrical isolation |
BC/X2X Link supply isolated from BC/X2X Link power supply I/O supply not isolated from I/O power supply, and RS232 not isolated from bus |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
See section "Derating". |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
12.5+0.2 mm |

Reviews