Fast delivery within 72 Hours
B&R X20PD0016
Integrated exchangeable microfuseMonitoring of the fusePotential for routing as neededDistribution of the load and electronics supplyIsolation from the internal I/O supply…
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
2-3 Days
From $20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From $40
-
Warranty 1 year
-
Free 30-Day returns
Description
Integrated exchangeable microfuseMonitoring of the fusePotential for routing as neededDistribution of the load and electronics supplyIsolation from the internal I/O supply
The potential distributor module provides 5x 24 VDC and 5x ground connections (from an external supply) at the terminals. There is no connection to the internal I/O supply, so this module only serves to distribute an external supply for the load and electronics supply. The externally fed 24 VDC supply is provided on the terminal connections through a replaceable microfuse. The 24 VDC feed and the functionality of the fuse are monitored.
Specification
| Potential distributor module |
5x 24 VDC on the terminals, 5x ground on the terminals |
|---|---|
| B&R ID code |
0x2680 |
| Status indicators |
Operating state, module status |
| Module run/error |
Yes, using LED status indicator and software |
| Fuse monitoring |
Yes, using LED status indicator and software |
| Bus |
0.12 W |
| Internal I/O |
– |
| External I/O |
1.15 W |
| Additional power dissipation caused by actuators (resistive) [W] |
– |
| CE |
Yes |
| UKCA |
Yes |
| CRA (Cyber Resilience Act) |
In preparation |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc |
| UL |
cULus E115267 |
| HazLoc |
cCSAus 244665 |
| DNV |
Temperature: B (0 to 55°C) |
| CCS |
Yes |
| LR |
ENV1 |
| KR |
Yes |
| ABS |
Yes |
| BV |
EC33B |
| KC |
Yes |
| Nominal input voltage |
24 VDC -15% / +20% external, ground external |
| Fuse |
Integrated 6.3 A, slow-blow, can be replaced |
| Reverse polarity protection |
No |
| Nominal output voltage |
24 VDC, ground |
| Permissible contact load |
10 A |
| On 24 VDC power supply |
Integrated fuse |
| On GND power supply |
No protection available |
| Horizontal |
Yes |
| Vertical |
Yes |
| 0 to 2000 m |
No limitation |
| >2000 m |
Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 |
IP20 |
| Horizontal mounting orientation |
-25 to 60°C |
| Vertical mounting orientation |
-25 to 50°C |
| Derating |
– |
| Storage |
5 to 95%, non-condensing |
| Transport |
5 to 95%, non-condensing |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x terminal block X20TB12 separately. |
| Pitch |
12.5+0.2 mm |

Reviews